Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 Tesla

Open access
Qiao, Ye, Steinman, David A., Qin, Qin, Etesami, Maryam, Schär, Michael, Astor, Brad C., Wasserman, Bruce A.·2011·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To develop a high isotropic‐resolution sequence to evaluate intracranial vessels at 3.0 Tesla (T). Materials and Methods: Thirteen healthy volunteers and 4 patients with intracranial stenosis were imaged at 3.0T using 0.5‐mm isotropic‐resolution three‐dimensional (3D) Volumetric ISotropic TSE Acquisition (VISTA; TSE, turbo spin echo), with conventional 2D‐TSE for comparison. VISTA was repeated for 6 volunteers and 4 patients at 0.4‐mm isotropic‐resolution to explore the trade‐off between SNR and voxel volume. Wall signal‐to‐noise‐ratio (SNR wall), wall‐lumen contrast‐to‐noise‐ratio (CNR wall‐lumen), lumen area (LA), wall area (WA), mean wall thickness (MWT), and maximum wall thickness (maxWT) were compared between 3D‐VISTA and 2D‐TSE sequences, as well as 3D images acquired at both resolutions. Reliability was assessed by intraclass correlations (ICC). Results: Compared with 2D‐TSE measurements, 3D‐VISTA provided 58% and 74% improvement in SNR wall and CNR wall‐lumen, respectively. LA, WA, MWT and maxWT from 3D and 2D techniques highly correlated (ICCs of 0.96, 0.95, 0.96, and 0.91, respectively). CNR wall‐lumen using 0.4‐mm resolution VISTA decreased by 27%, compared with 0.5‐mm VISTA but with reduced partial‐volume‐based overestimation of wall thickness. Reliability for 3D measurements was good to excellent. Conclusion: The 3D‐VISTA provides SNR‐efficient, highly reliable measurements of intracranial vessels at high isotropic‐resolution, enabling broad coverage in a clinically acceptable time. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22592

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 267

Metadata

Authors
Qiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-06-22
Volume
34
Issue
1
Pages
22-30
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1979574276
Cited by
267
References
29
FWCI
6.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 Tesla. https://app.cochat.ai/papers/10.1002/jmri.22592
The paper
Qiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A. (2011). Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 Tesla. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22592

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.