The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Intracranial arterial wall imaging using three‐dimensional high isotropic resolution black blood MRI at 3.0 Tesla
Open accessAbstract
Purpose: To develop a high isotropic‐resolution sequence to evaluate intracranial vessels at 3.0 Tesla (T). Materials and Methods: Thirteen healthy volunteers and 4 patients with intracranial stenosis were imaged at 3.0T using 0.5‐mm isotropic‐resolution three‐dimensional (3D) Volumetric ISotropic TSE Acquisition (VISTA; TSE, turbo spin echo), with conventional 2D‐TSE for comparison. VISTA was repeated for 6 volunteers and 4 patients at 0.4‐mm isotropic‐resolution to explore the trade‐off between SNR and voxel volume. Wall signal‐to‐noise‐ratio (SNR wall), wall‐lumen contrast‐to‐noise‐ratio (CNR wall‐lumen), lumen area (LA), wall area (WA), mean wall thickness (MWT), and maximum wall thickness (maxWT) were compared between 3D‐VISTA and 2D‐TSE sequences, as well as 3D images acquired at both resolutions. Reliability was assessed by intraclass correlations (ICC). Results: Compared with 2D‐TSE measurements, 3D‐VISTA provided 58% and 74% improvement in SNR wall and CNR wall‐lumen, respectively. LA, WA, MWT and maxWT from 3D and 2D techniques highly correlated (ICCs of 0.96, 0.95, 0.96, and 0.91, respectively). CNR wall‐lumen using 0.4‐mm resolution VISTA decreased by 27%, compared with 0.5‐mm VISTA but with reduced partial‐volume‐based overestimation of wall thickness. Reliability for 3D measurements was good to excellent. Conclusion: The 3D‐VISTA provides SNR‐efficient, highly reliable measurements of intracranial vessels at high isotropic‐resolution, enabling broad coverage in a clinically acceptable time. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Sacco, R. L., Kargman, D. E., Gu, Q., & Zamanillo, M. C. (1995) · Stroke · doi:10.1161/01.str.26.1.14 · Cited by 974
Statistical Methods for Rates and Proportions
Conover, W. J. (1974) · Technometrics · doi:10.1080/00401706.1974.10489195 · Cited by 877
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Race and Sex Differences in the Distribution of Cerebral Atherosclerosis
Wityk, R. J., Lehman, D., Klag, M., Coresh, J., Ahn, H., & Litt, B. (1996) · Stroke · doi:10.1161/01.str.27.11.1974 · Cited by 518
Yuan, C., Zhang, S.-X., Polissar, N. L., Echelard, D., Ortiz, G., Davis, J. W., Ellington, E., Ferguson, M. S., & Hatsukami, T. S. (2002) · Circulation · doi:10.1161/hc0202.102121 · Cited by 454
Assessing intrarater, interrater, and test-retest reliability of continuous measurements
Rousson, V., Gasser, T., & Seifert, B. (2002) · Statistics in Medicine · doi:10.1002/sim.1253 · Cited by 415
Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20863 · Cited by 335
Wasserman, B. A., Smith, W. I., Trout, H. H., Cannon, R. O., Balaban, R. S., & Arai, A. E. (2002) · Radiology · doi:10.1148/radiol.2232010659 · Cited by 333
Self-citationRoutine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10391 · Cited by 244
Autopsy Prevalence of Intracranial Atherosclerosis in Patients With Fatal Stroke
Mazighi, M., Labreuche, J., Gongora-Rivera, F., Duyckaerts, C., Hauw, J.-J., & Amarenco, P. (2008) · Stroke · doi:10.1161/strokeaha.107.496513 · Cited by 242
Xu, W.-H., Li, M.-L., Gao, S., Ni, J., Zhou, L.-X., Yao, M., Peng, B., Feng, F., Jin, Z.-Y., & Cui, L.-Y. (2010) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2010.06.035 · Cited by 224
T 2 -Weighted Contrast for NMR Characterization of Human Atherosclerosis
Toussaint, J.-F., Southern, J. F., Fuster, V., & Kantor, H. L. (1995) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvb.15v10.1533 · Cited by 218
Low-Grade Carotid Stenosis: Looking Beyond the Lumen With MRI
Wasserman, B. A., Wityk, R. J., Trout, H. H., & Virmani, R. (2005) · Stroke · doi:10.1161/01.str.0000185726.83152.00 · Cited by 196
Self-citationFan, Z., Zhang, Z., Chung, Y., Weale, P. J., Zuehlsdorff, S., Carr, J., & Li, D. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22058 · Cited by 127
Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
Li, M. L., Xu, W., Song, L., Feng, F., You, H., Ni, J., Gao, S., Cui, L., & Jin, Z. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.10.019 · Cited by 124
Three-Dimensional T2-Weighted MRI of the Human Femoral Arterial Vessel Wall at 3.0 Tesla
Zhang, Z., Fan, Z., Carroll, T. J., Chung, Y.-C., Weale, P. J., Jerec̆ić, R., & Li, D. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b4c218 · Cited by 67
Jara, H. J., YU, B. C., Caruthers, S. D., Melhem, E. R., & Yucel, E. K. (1999) · Magnetic Resonance in Medicine · Cited by 61
Consensus Conference on Intracranial Atherosclerotic Disease: Rationale, Methodology, and Results
Qureshi, A. I., Feldmann, E. G., Gomez, C. R., Johnston, S. C., Kasner, S. E., Quick, D. C., Rasmussen, P. A., Suri, M. F. K., Taylor, R. A., & Zaidat, O. O. (2009) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2009.00414.x · Cited by 59
Tailoring the flow sensitivity of fast spin‐echo sequences for noncontrast peripheral MR angiography
Storey, P., Atanasova, I. P., Lim, R., Xu, J., Kim, D. C., Chen, Q., & Lee, V. S. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22510 · Cited by 50
Zhang, S., Cai, J., Luo, Y., et al. (2003) · Radiology · doi:10.1148/radiol.2281020484 · Cited by 47
Koktzoglou, I., Chung, Y.-C., Carroll, T. J., Simonetti, O. P., Morasch, M. D., & Li, D. (2007) · Radiology · doi:10.1148/radiol.2431060310 · Cited by 47
Intracranial large artery occlusive disease
Caplan, L. R. (2008) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-008-0028-8 · Cited by 9
Greenman, R. L., Wang, X., Ngo, L. H., Marquis, R. P., & Farrar, N. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.06.004 · Cited by 9
Cited by
Mandell, D. M., Mossa-Basha, M., Qiao, Y., Hess, C. P., Hui, F., Matouk, C., Johnson, M. H., Daemen, M. J. A. P., Vossough, A., Edjlali, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4893 · Cited by 691
Self-citationOptimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Qiao, Y., Zeiler, S. R., Mirbagheri, S., Leigh, R., Urrutia, V., Wityk, R., & Wasserman, B. A. (2014) · Radiology · doi:10.1148/radiol.13122812 · Cited by 329
Self-citation
Metadata
- Authors
- Qiao, Y., Steinman, D. A., Qin, Q., Etesami, M., Schär, M., Astor, B. C., & Wasserman, B. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-06-22
- Volume
- 34
- Issue
- 1
- Pages
- 22-30
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1979574276
- Cited by
- 267
- References
- 29
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.