The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Tumor response assessments with diffusion and perfusion MRI
Abstract
There is an increasing awareness that the evaluation of tumor response to oncologic treatments based solely on anatomic imaging assessments face many limitations, particularly in this era of novel biologic targeted therapies. Functional imaging techniques such as diffusion‐weighted (DW) and dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) have the ability to depict important tumor biologic features and are able to predict therapy response based on assessments of cellularity and tumor vascularity, which often precede morphologic alterations. In this article we focus on DW‐MRI and DCE‐MRI as response parameters addressing the technologies involved, quantification methods, and validation for each technique and their current role in imaging response to conventional and novel therapies. We also discuss the challenges that lie ahead in the deployment of these imaging methods into the clinical environment. J. Magn. Reson. Imaging 2012;35:745‐763. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saltz, L. B., Clarke, S., Díaz-Rubio, E., Scheithauer, W., Figer, A., Wong, R., Koski, S., Lichinitser, M., Yang, T.-S., Rivera, F., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.9930 · Cited by 2,955
Normalizing tumor vasculature with anti-angiogenic therapy: A new paradigm for combination therapy
Jain, R. K. (2001) · Nature Medicine · doi:10.1038/nm0901-987 · Cited by 2,184
Batchelor, T. T., Duda, D. G., di Tomaso, E., Ancukiewicz, M., Plotkin, S. R., Gerstner, E., Eichler, A. F., Drappatz, J., Hochberg, F. H., Benner, T., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.26.3988 · Cited by 520
Quantifying spatial heterogeneity in dynamic contrast‐enhanced MRI parameter maps
Rose, C. J., Mills, S. J., O'Connor, J. P. B., Buonaccorsi, G. A., Roberts, C., Watson, Y., Cheung, S., Zhao, S., Whitcher, B., Jackson, A., et al. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22003 · Cited by 125
Cited by
Shukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Rosenkrantz, A. B., Padhani, A. R., Chenevert, T. L., Koh, D., De Keyzer, F., Taouli, B., & Le Bihan, D. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24985 · Cited by 381
Self-citation
Metadata
- Authors
- Li, S. P., & Padhani, A. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2012-03-20
- Volume
- 35
- Issue
- 4
- Pages
- 745-763
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2007086375
- Cited by
- 180
- References
- 4
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tumor response assessments with diffusion and perfusion MRI. https://app.cochat.ai/papers/10.1002/jmri.22838
- The paper
- Li, S. P., & Padhani, A. R. (2012). Tumor response assessments with diffusion and perfusion MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22838
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.