The DOI matches its Crossref record.
Establishing a baseline phase behavior in magnetic resonance imaging to determine normal vs. abnormal iron content in the brain
Open accessAbstract
Purpose: To establish a baseline of phase differences between tissues in a number of regions of the human brain as a means of detecting iron abnormalities using magnetic resonance imaging (MRI). Materials and Methods: A fully flow‐compensated, three‐dimensional (3D), high‐resolution, gradient‐echo (GRE) susceptibility‐weighted imaging (SWI) sequence was used to collect magnitude and phase data at 1.5T. The phase images were high‐pass‐filtered and processed region by region with hand‐drawn areas. The regions evaluated included the motor cortex (MC), putamen (PUT), globus pallidus (GP), caudate nucleus (CN), substantia nigra (SN), and red nucleus (RN). A total of 75 subjects, ranging in age from 55 to 89 years, were analyzed. Results: The phase was found to have a Gaussian‐like distribution with a standard deviation (SD) of 0.046 radians on a pixel‐by‐pixel basis. Most regions of interest (ROIs) contained at least 100 pixels, giving a standard error of the mean (SEM) of 0.0046 radians or less. In the MC, phase differences were found to be roughly 0.273 radians between CSF and gray matter (GM), and 0.083 radians between CSF and white matter (WM). The difference between CSF and the GP was 0.201 radians, and between CSF and the CN (head) it was 0.213 radians. For CSF and the PUT (the lower outer part) the difference was 0.449 radians, and between CSF and the RN (third slice vascularized region) it was 0.353 radians. Finally, the phase difference between CSF and SN was 0.345 radians. Conclusion: The Gaussian‐like distributions in phase make it possible to predict deviations from normal phase behavior for tissues in the brain. Using phase as an iron marker may be useful for studying absorption of iron in diseases such as Parkinson's, Huntington's, neurodegeneration with brain iron accumulation (NBIA), Alzheimer's, and multiple sclerosis (MS), and other iron‐related diseases. The phases quoted here will serve as a baseline for future studies that look for changes in iron content. J. Magn. Reson. Imaging 2007;26:256–264. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 2
Mittal, S., Wu, Z., Neelavalli, J., & Haacke, E. M. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1461 · Cited by 769
Self-citationPrinciples, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications
Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M., & Haacke, E. M. (2009) · RadioGraphics · doi:10.1148/rg.295095034 · Cited by 740
Self-citationSchweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Metadata
- Authors
- Haacke, E. M., Ayaz, M., Khan, A., Manova, E. S., Krishnamurthy, B., Gollapalli, L., Ciulla, C., Kim, I., Petersen, F., & Kirsch, W.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-07-25
- Volume
- 26
- Issue
- 2
- Pages
- 256-264
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2097351556
- Cited by
- 241
- References
- 0
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Establishing a baseline phase behavior in magnetic resonance imaging to determine normal vs. abnormal iron content in the brain. https://app.cochat.ai/papers/10.1002/jmri.22987
- The paper
- Haacke, E. M., Ayaz, M., Khan, A., Manova, E. S., Krishnamurthy, B., Gollapalli, L., Ciulla, C., Kim, I., Petersen, F., & Kirsch, W. (2007). Establishing a baseline phase behavior in magnetic resonance imaging to determine normal vs. abnormal iron content in the brain. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.