The DOI matches its Crossref record.
Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications
Open accessAbstract
T2* relaxation refers to decay of transverse magnetization caused by a combination of spin-spin relaxation and magnetic field inhomogeneity. T2* relaxation is seen only with gradient-echo (GRE) imaging because transverse relaxation caused by magnetic field inhomogeneities is eliminated by the 180 degrees pulse at spin-echo imaging. T2* relaxation is one of the main determinants of image contrast with GRE sequences and forms the basis for many magnetic resonance (MR) applications, such as susceptibility-weighted (SW) imaging, perfusion MR imaging, and functional MR imaging. GRE sequences can be made predominantly T2* weighted by using a low flip angle, long echo time, and long repetition time. GRE sequences with T2*-based contrast are used to depict hemorrhage, calcification, and iron deposition in various tissues and lesions. SW imaging uses phase information in addition to T2*-based contrast to exploit the magnetic susceptibility differences of the blood and of iron and calcification in various tissues. Perfusion MR imaging exploits the signal intensity decrease that occurs with the passage of a high concentration of gadopentetate dimeglumine through the microvasculature. Change in oxygen saturation during specific tasks changes the local T2*, which leads to the blood oxygen level-dependent effect seen at functional MR imaging. The basics of T2* relaxation, T2*-weighted sequences, and their clinical applications are presented, followed by the principles, techniques, and clinical uses of four T2*-based applications, including SW imaging, perfusion MR imaging, functional MR imaging, and iron overload imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Myelin and iron concentration in the human brain: a quantitative study of MRI contrast
Stüber, C., Morawski, M., Schäfer, A., Labadie, C., Wähnert, M., Leuze, C., Streicher, M., Barapatre, N., Reimann, K., Geyer, S., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.02.026 · Cited by 635
Cooperative, O. B. O. T. N., Sati, P., Oh, J., Constable, R. T., Evangelou, N., Guttmann, C. R. G., Henry, R. G., Klawiter, E. C., Mainero, C., Massacesi, L., et al. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.166 · Cited by 426
Xu, J., Chen, Z., Yu, F., Liu, H., Ma, C., Xie, D., Hu, X., Leak, R. K., Chou, S. H. Y., Stetler, R. A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018497117 · Cited by 180
Arshad, M., Stanley, J. A., & Raz, N. (2017) · Human Brain Mapping · doi:10.1002/hbm.23481 · Cited by 131
In vivo evidence of neurophysiological maturation of the human adolescent striatum
Larsen, B., & Luna, B. (2015) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2014.12.003 · Cited by 78
Metadata
- Authors
- Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M., & Haacke, E. M.
- Venue
- RadioGraphics
- Published
- 2009-09
- Volume
- 29
- Issue
- 5
- Pages
- 1433-1449
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2132514417
- Cited by
- 740
- References
- 0
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications. https://app.cochat.ai/papers/10.1148/rg.295095034
- The paper
- Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M., & Haacke, E. M. (2009). Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications. RadioGraphics. https://doi.org/10.1148/rg.295095034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.