The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Fast image reconstruction with L2‐regularization
Open accessAbstract
Purpose: We introduce L2‐regularized reconstruction algorithms with closed‐form solutions that achieve dramatic computational speed‐up relative to state of the art L1‐ and L2‐based iterative algorithms while maintaining similar image quality for various applications in MRI reconstruction. Materials and Methods: We compare fast L2‐based methods to state of the art algorithms employing iterative L1‐ and L2‐regularization in numerical phantom and in vivo data in three applications; (i) Fast Quantitative Susceptibility Mapping (QSM), (ii) Lipid artifact suppression in Magnetic Resonance Spectroscopic Imaging (MRSI), and (iii) Diffusion Spectrum Imaging (DSI). In all cases, proposed L2‐based methods are compared with the state of the art algorithms, and two to three orders of magnitude speed up is demonstrated with similar reconstruction quality. Results: The closed‐form solution developed for regularized QSM allows processing of a three‐dimensional volume under 5 s, the proposed lipid suppression algorithm takes under 1 s to reconstruct single‐slice MRSI data, while the PCA based DSI algorithm estimates diffusion propagators from undersampled q‐space for a single slice under 30 s, all running in Matlab using a standard workstation. Conclusion: For the applications considered herein, closed‐form L2‐regularization can be a faster alternative to its iterative counterpart or L1‐based iterative algorithms, without compromising image quality. J. Magn. Reson. Imaging 2014;40:181–191 © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Zhou, Y., Chang, F.-J., Chang, L.-C., Kao, I.-F., & Wang, Y.-S. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.10.243 · Cited by 286
Li, H.-L., Pang, Y.-H., & Liu, B. (2021) · Nucleic Acids Research · doi:10.1093/nar/gkab829 · Cited by 269
Metadata
- Authors
- Bilgic, B., Chatnuntawech, I., Fan, A. P., Setsompop, K., Cauley, S. F., Wald, L. L., & Adalsteinsson, E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2013-11-04
- Volume
- 40
- Issue
- 1
- Pages
- 181-191
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2121142820
- Cited by
- 185
- References
- 4
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.