The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload
Open accessAbstract
Purpose: To explore the use and reproducibility of magnetic resonance‐derived myocardial T1 mapping in patients with iron overload. Materials and Methods: The research received ethics committee approval and all patients provided written informed consent. This was a prospective study of 88 patients and 67 healthy volunteers. Thirty‐five patients underwent repeat scanning for reproducibility. T1 mapping used the shortened modified Look–Locker inversion recovery sequence (ShMOLLI) with a second, confirmatory MOLLI sequence in the reproducibility group. T2* was performed using a commercially available sequence. The analysis of the T2* interstudy reproducibility data was performed by two different research groups using two different methods. Results: Myocardial T1 was lower in patients than healthy volunteers (836 ± 138 msec vs. 968 ± 32 msec, P < 0.0001). Myocardial T1 correlated with T2* (R = 0.79, P < 0.0001). No patient with low T2* had normal T1, but 32% (n = 28) of cases characterized by a normal T2* had low myocardial T1. Interstudy reproducibility of either T1 sequence was significantly better than T2*, with the results suggesting that the use of T1 in clinical trials could decrease potential sample sizes by 7‐fold. Conclusion: Myocardial T1 mapping is an alternative method for cardiac iron quantification. T1 mapping shows the potential for improved detection of mild iron loading. The superior reproducibility of T1 has potential implications for clinical trial design and therapeutic monitoring. J. Magn. Reson. Imaging 2015;41:1505–1511. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Cited by
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001063 · Cited by 4,922
2022 AHA/ACC/HFSA Guideline for the Management of Heart Failure
Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., Deswal, A., Drazner, M. H., Dunlay, S. M., Evers, L. R., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.12.012 · Cited by 2,862
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Self-citationCardiac T1 Mapping and Extracellular Volume (ECV) in clinical practice: a comprehensive review
Haaf, P., Garg, P., Messroghli, D. R., Broadbent, D. A., Greenwood, J. P., & Plein, S. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0308-4 · Cited by 959
Taylor, A. J., Salerno, M., Dharmakumar, R., & Jerosch-Herold, M. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.11.005 · Cited by 563
Metadata
- Authors
- Sado, D. M., Maestrini, V., Piechnik, S. K., Banypersad, S. M., White, S. K., Flett, A. S., Robson, M. D., Neubauer, S., Ariti, C., Arai, A., Kellman, P., Yamamura, J., Schoennagel, B. P., Shah, F., Davis, B., Trompeter, S., Walker, M., Porter, J., & Moon, J. C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-08-08
- Volume
- 41
- Issue
- 6
- Pages
- 1505-1511
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1959647737
- Cited by
- 175
- References
- 2
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload. https://app.cochat.ai/papers/10.1002/jmri.24727
- The paper
- Sado, D. M., Maestrini, V., Piechnik, S. K., Banypersad, S. M., White, S. K., Flett, A. S., Robson, M. D., Neubauer, S., Ariti, C., Arai, A., Kellman, P., Yamamura, J., Schoennagel, B. P., Shah, F., Davis, B., Trompeter, S., Walker, M., Porter, J., & Moon, J. C. (2015). Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24727
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.