MRI phenotype of breast cancer: Kinetic assessment for molecular subtypes
Open accessThe DOI matches its Crossref record.
Abstract
Purpose: To evaluate the dynamic contrast‐enhanced magnetic resonance imaging (MRI) kinetic characteristics of newly diagnosed breast cancer molecular subtypes. Materials and Methods: Breast MRI examinations of 112 patients with newly diagnosed breast cancer were reviewed. Cases of newly diagnosed invasive ductal carcinoma were sorted by molecular subtype (28 TN, 11 HER2 +, 73 Lum A/B) and MRI field strength, with lesion segmentation and kinetic analyses performed on a dedicated workstation. For kinetic assessment, 50% and 100% thresholds were employed for display of medium and rapid uptake. Kinetic profiles in terms of percent volume for six kinetic types (medium‐persistent, medium‐plateau, medium‐washout, fast‐persistent, fast‐plateau, fast‐washout) relative to the whole volume of the lesion were obtained. Statistical analysis of the kinetic profiles was performed using Welch's t‐test. Results: Percent volume of HER2‐positive lesions with >100% uptake at early phase on 3T strength MRI exams was significantly greater compared with luminal A/B (93.8 ± 0.92 vs. 77.3 ± 7.2; P < 0.01) and triple negative (93.8 ± 0.92 vs. 81.3 ± 8.2; P < 0.05) subtypes. The >50% early phase uptake for HER2+ lesions was also higher than Lum A/B (99.1 ± 0.73 vs. 93.6 ± 3.05; P < 0.01) at 3T. In the 1.5T subgroup the percent volume of HER2+ tumors with >50% and >100% early phase uptake trended higher than Lum A/B lesions without reaching significance. Conclusion: The percent volume of HER2‐positive tumors demonstrating rapid early contrast uptake is significantly increased compared to other molecular subtypes. J. Magn. Reson. Imaging 2015;42:920–924.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Braman, N. M., Etesami, M., Prasanna, P., Dubchuk, C., Gilmore, H., Tiwari, P., Plecha, D., & Madabhushi, A. (2017) · Breast Cancer Research · doi:10.1186/s13058-017-0846-1 · Cited by 632
Li, H., Zhu, Y., Burnside, E. S., Huang, E., Drukker, K., Hoadley, K. A., Fan, C., Conzen, S. D., Zuley, M., Net, J. M., et al. (2016) · npj Breast Cancer · doi:10.1038/npjbcancer.2016.12 · Cited by 364
Braman, N., Prasanna, P., Whitney, J., Singh, S., Beig, N., Etesami, M., Bates, D. D. B., Gallagher, K., Bloch, B. N., Vulchi, M., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.2561 · Cited by 327
Saha, A., Harowicz, M. R., Grimm, L. J., Kim, C. E., Ghate, S. V., Walsh, R., & Mazurowski, M. A. (2018) · British Journal of Cancer · doi:10.1038/s41416-018-0185-8 · Cited by 310
Precision medicine and radiogenomics in breast cancer: new approaches toward diagnosis and treatment
Pinker, K., Chin, J., Melsaether, A. N., Morris, E. A., & Moy, L. (2018) · Radiology · doi:10.1148/radiol.2018172171 · Cited by 275
Burnside, E. S., Drukker, K., Li, H., Bonaccio, E., Zuley, M., Ganott, M., Net, J. M., Sutton, E. J., Brandt, K. R., Whitman, G. J., et al. (2016) · Cancer · doi:10.1002/cncr.29791 · Cited by 71
Wu, J., Li, X., Teng, X., Rubin, D. L., Napel, S., Daniel, B. L., & Li, R. (2018) · Breast Cancer Research · doi:10.1186/s13058-018-1039-2 · Cited by 53
Metadata
- Authors
- Blaschke, E., & Abe, H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2015-03-09
- Volume
- 42
- Issue
- 4
- Pages
- 920-924
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1490299822
- Cited by
- 70
- References
- 0
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.