Open access
Heba, Elhamy R., Desai, Ajinkya, Zand, Kevin A., Hamilton, Gavin, Wolfson, Tanya, Schlein, Alexandra N., Gamst, Anthony, Loomba, Rohit, Sirlin, Claude B., Middleton, Michael S. · 2016 · Journal of Magnetic Resonance Imaging
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To determine the accuracy and the effect of possible subject‐based confounders of magnitude‐based magnetic resonance imaging (MRI) for estimating hepatic proton density fat fraction (PDFF) for different numbers of echoes in adults with known or suspected nonalcoholic fatty liver disease, using MR spectroscopy (MRS) as a reference. Materials and Methods: In this retrospective analysis of 506 adults, hepatic PDFF was estimated by unenhanced 3.0T MRI, using right‐lobe MRS as reference. Regions of interest placed on source images and on six‐echo parametric PDFF maps were colocalized to MRS voxel location. Accuracy using different numbers of echoes was assessed by regression and Bland–Altman analysis; slope, intercept, average bias, and R 2 were calculated. The effect of age, sex, and body mass index (BMI) on hepatic PDFF accuracy was investigated using multivariate linear regression analyses. Results: MRI closely agreed with MRS for all tested methods. For three‐ to six‐echo methods, slope, regression intercept, average bias, and R 2 were 1.01–0.99, 0.11–0.62%, 0.24–0.56%, and 0.981–0.982, respectively. Slope was closest to unity for the five‐echo method. The two‐echo method was least accurate, underestimating PDFF by an average of 2.93%, compared to an average of 0.23–0.69% for the other methods. Statistically significant but clinically nonmeaningful effects on PDFF error were found for subject BMI (P range: 0.0016 to 0.0783), male sex (P range: 0.015 to 0.037), and no statistically significant effect was found for subject age (P range: 0.18‐0.24). Conclusion: Hepatic magnitude‐based MRI PDFF estimates using three, four, five, and six echoes, and six‐echo parametric maps are accurate compared to reference MRS values, and that accuracy is not meaningfully confounded by age, sex, or BMI. J. Magn. Reson. Imaging 2016;43:398–406.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.25006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 60

Metadata

Authors
Heba, E. R., Desai, A., Zand, K. A., Hamilton, G., Wolfson, T., Schlein, A. N., Gamst, A., Loomba, R., Sirlin, C. B., & Middleton, M. S.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2015-07-22
Volume
43
Issue
2
Pages
398-406
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1814376565
Cited by
60
References
1
FWCI
4.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and the effect of possible subject‐based confounders of magnitude‐based MRI for estimating hepatic proton density fat fraction in adults, using MR spectroscopy as reference. https://app.cochat.ai/papers/10.1002/jmri.25006
The paper
Heba, E. R., Desai, A., Zand, K. A., Hamilton, G., Wolfson, T., Schlein, A. N., Gamst, A., Loomba, R., Sirlin, C. B., & Middleton, M. S. (2016). Accuracy and the effect of possible subject‐based confounders of magnitude‐based MRI for estimating hepatic proton density fat fraction in adults, using MR spectroscopy as reference. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.25006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.