Accuracy and the effect of possible subject‐based confounders of magnitude‐based MRI for estimating hepatic proton density fat fraction in adults, using MR spectroscopy as reference
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To determine the accuracy and the effect of possible subject‐based confounders of magnitude‐based magnetic resonance imaging (MRI) for estimating hepatic proton density fat fraction (PDFF) for different numbers of echoes in adults with known or suspected nonalcoholic fatty liver disease, using MR spectroscopy (MRS) as a reference. Materials and Methods: In this retrospective analysis of 506 adults, hepatic PDFF was estimated by unenhanced 3.0T MRI, using right‐lobe MRS as reference. Regions of interest placed on source images and on six‐echo parametric PDFF maps were colocalized to MRS voxel location. Accuracy using different numbers of echoes was assessed by regression and Bland–Altman analysis; slope, intercept, average bias, and R 2 were calculated. The effect of age, sex, and body mass index (BMI) on hepatic PDFF accuracy was investigated using multivariate linear regression analyses. Results: MRI closely agreed with MRS for all tested methods. For three‐ to six‐echo methods, slope, regression intercept, average bias, and R 2 were 1.01–0.99, 0.11–0.62%, 0.24–0.56%, and 0.981–0.982, respectively. Slope was closest to unity for the five‐echo method. The two‐echo method was least accurate, underestimating PDFF by an average of 2.93%, compared to an average of 0.23–0.69% for the other methods. Statistically significant but clinically nonmeaningful effects on PDFF error were found for subject BMI (P range: 0.0016 to 0.0783), male sex (P range: 0.015 to 0.037), and no statistically significant effect was found for subject age (P range: 0.18‐0.24). Conclusion: Hepatic magnitude‐based MRI PDFF estimates using three, four, five, and six echoes, and six‐echo parametric maps are accurate compared to reference MRS values, and that accuracy is not meaningfully confounded by age, sex, or BMI. J. Magn. Reson. Imaging 2016;43:398–406.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metformin reverses fatty liver disease in obese, leptin-deficient mice.
Lin, H. Z., Yang, S. Q., Chuckaree, C., Kuhajda, F., Ronnet, G., & Diehl, A. M. (2000) · Nature Medicine · doi:10.1038/79697 · Cited by 673
Cited by
Chalasani, N., Younossi, Z., Lavine, J. E., Charlton, M., Cusi, K., Rinella, M., Harrison, S. A., Brunt, E. M., & Sanyal, A. J. (2018) · Hepatology · doi:10.1002/hep.29367 · Cited by 7,239
“MR imaging, either by spectroscopy((92)) or by proton density fat fraction,((93,94)) is an excellent noninvasive modality for quantifying HS and is being widely used in NAFLD clinical trials.”
MethodDulai, P. S., Sirlin, C. B., & Loomba, R. (2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.06.005 · Cited by 356
Self-citationCusi, K., Abdelmalek, M. F., Apovian, C. M., Balapattabi, K., Bannuru, R. R., Barb, D., Bardsley, J. K., Beverly, E. A., Corbin, K. D., ElSayed, N. A., et al. (2025) · Diabetes Care · doi:10.2337/dci24-0094 · Cited by 332
Liver fat imaging—a clinical overview of ultrasound, CT, and MR imaging
Zhang, Y. N., Fowler, K. J., Hamilton, G., Cui, J. Y., Sy, E. Z., Balanay, M., Hooker, J. C., Szeverenyi, N., & Sirlin, C. B. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20170959 · Cited by 304
Self-citationHolmer, M., Lindqvist, C., Petersson, S., Moshtaghi-Svensson, J., Tillander, V., Brismar, T. B., Hagström, H., & Stål, P. (2021) · JHEP Reports · doi:10.1016/j.jhepr.2021.100256 · Cited by 224
“Twenty-four to 72 h before randomisation all participants underwent MRS. 19 MRS data were analysed using the Java-based magnetic resonance user interface software (JAVA, Sun Micro-systems, Menlo Park, California, US) 20 and the fat and water peaks were quanti fi ed using the advanced method for an…”
Jayakumar, S., Middleton, M. S., Lawitz, E. J., Mantry, P. S., Caldwell, S. H., Arnold, H., Mae Diehl, A., Ghalib, R., Elkhashab, M., Abdelmalek, M. F., et al. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2018.09.024 · Cited by 208
Self-citationThe Role of Multiparametric US of the Liver for the Evaluation of Nonalcoholic Steatohepatitis
Sugimoto, K., Moriyasu, F., Oshiro, H., Takeuchi, H., Abe, M., Yoshimasu, Y., Kasai, Y., Sakamaki, K., Hara, T., & Itoi, T. (2020) · Radiology · doi:10.1148/radiol.2020192665 · Cited by 189
Qadri, S., Vartiainen, E., Lahelma, M., Porthan, K., Tang, A., Idilman, I. S., Runge, J. H., Juuti, A., Penttilä, A. K., Dabek, J., et al. (2024) · JHEP Reports · doi:10.1016/j.jhepr.2023.100928 · Cited by 55
“42 Histological assessment of steatosis is subjective and inherently semiquantitative, bearing several well-known limitations such as inter-rater error and the biopsy-associated sampling error.”
Self-citation
Metadata
- Authors
- Heba, E. R., Desai, A., Zand, K. A., Hamilton, G., Wolfson, T., Schlein, A. N., Gamst, A., Loomba, R., Sirlin, C. B., & Middleton, M. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2015-07-22
- Volume
- 43
- Issue
- 2
- Pages
- 398-406
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1814376565
- Cited by
- 60
- References
- 1
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.