Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: Preliminary findings from a multi‐institutional study
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate in a multi-institutional study whether radiomic features useful for prostate cancer (PCa) detection from 3 Tesla (T) multi-parametric MRI (mpMRI) in the transition zone (TZ) differ from those in the peripheral zone (PZ). MATERIALS AND METHODS: 3T mpMRI, including T2-weighted (T2w), apparent diffusion coefficient (ADC) maps, and dynamic contrast-enhanced MRI (DCE-MRI), were retrospectively obtained from 80 patients at three institutions. This study was approved by the institutional review board of each participating institution. First-order statistical, co-occurrence, and wavelet features were extracted from T2w MRI and ADC maps, and contrast kinetic features were extracted from DCE-MRI. Feature selection was performed to identify 10 features for PCa detection in the TZ and PZ, respectively. Two logistic regression classifiers used these features to detect PCa and were evaluated by area under the receiver-operating characteristic curve (AUC). Classifier performance was compared with a zone-ignorant classifier. RESULTS: Radiomic features that were identified as useful for PCa detection differed between TZ and PZ. When classification was performed on a per-voxel basis, a PZ-specific classifier detected PZ tumors on an independent test set with significantly higher accuracy (AUC = 0.61-0.71) than a zone-ignorant classifier trained to detect cancer throughout the entire prostate (P < 0.05). When classifiers were evaluated on MRI data from multiple institutions, statistically similar AUC values (P > 0.14) were obtained for all institutions. CONCLUSION: A zone-aware classifier significantly improves the accuracy of cancer detection in the PZ. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:184-193.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“Additionally, for patients who were imaged using an endorectal probe, the bias field artifact occurring on T2w and DCE MRI was corrected by the N3 algorithm.(29)”
MethodMultichannel texture analysis using localized spatial filters
Bovik, A. C., Clark, M., & Geisler, W. S. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.41384 · Cited by 1,382
Wibmer, A., Hricak, H., Gondo, T., Matsumoto, K., Veeraraghavan, H., Fehr, D., Zheng, J., Goldman, D., Moskowitz, C., Fine, S. W., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3701-8 · Cited by 391
Vignati, A., Mazzetti, S., Giannini, V, Russo, F., Bollito, E., Porpiglia, F., Stasi, M., & Regge, D. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/7/2685 · Cited by 122
Cited by
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
Tracking tumor biology with radiomics: a systematic review utilizing a radiomics quality score
Sanduleanu, S., Woodruff, H. C., de Jong, E. E. C., van Timmeren, J. E., Jochems, A., Dubois, L., & Lambin, P. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.03.033 · Cited by 242
“[33] MR PC Histopathologic Gleason tumor grading 29.”
Belue, M. J., Harmon, S. A., Lay, N. S., Daryanani, A., Phelps, T. E., Choyke, P. L., & Turkbey, B. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2022.05.022 · Cited by 27
Metadata
- Authors
- Ginsburg, S. B., Algohary, A., Pahwa, S., Gulani, V., Ponsky, L., Aronen, H. J., Boström, P. J., Böhm, M., Haynes, A., Brenner, P., Delprado, W., Thompson, J., Pulbrock, M., Taimen, P., Villani, R., Stricker, P., Rastinehad, A. R., Jambor, I., & Madabhushi, A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2016-12-19
- Volume
- 46
- Issue
- 1
- Pages
- 184-193
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2562490391
- Cited by
- 143
- References
- 5
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: Preliminary findings from a multi‐institutional study. https://app.cochat.ai/papers/10.1002/jmri.25562
- The paper
- Ginsburg, S. B., Algohary, A., Pahwa, S., Gulani, V., Ponsky, L., Aronen, H. J., Boström, P. J., Böhm, M., Haynes, A., Brenner, P., Delprado, W., Thompson, J., Pulbrock, M., Taimen, P., Villani, R., Stricker, P., Rastinehad, A. R., Jambor, I., & Madabhushi, A. (2017). Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: Preliminary findings from a multi‐institutional study. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.25562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.