The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Deep neural network‐based computer‐assisted detection of cerebral aneurysms in MR angiography
Abstract
Background: The usefulness of computer‐assisted detection (CAD) for detecting cerebral aneurysms has been reported; therefore, the improved performance of CAD will help to detect cerebral aneurysms. Purpose: To develop a CAD system for intracranial aneurysms on unenhanced magnetic resonance angiography (MRA) images based on a deep convolutional neural network (CNN) and a maximum intensity projection (MIP) algorithm, and to demonstrate the usefulness of the system by training and evaluating it using a large dataset. Study Type: Retrospective study. Subjects: There were 450 cases with intracranial aneurysms. The diagnoses of brain aneurysms were made on the basis of MRA, which was performed as part of a brain screening program. Field Strength/Sequence: Noncontrast‐enhanced 3D time‐of‐flight (TOF) MRA on 3T MR scanners. Assessment: In our CAD, we used a CNN classifier that predicts whether each voxel is inside or outside aneurysms by inputting MIP images generated from a volume of interest (VOI) around the voxel. The CNN was trained in advance using manually inputted labels. We evaluated our method using 450 cases with intracranial aneurysms, 300 of which were used for training, 50 for parameter tuning, and 100 for the final evaluation. Statistical Tests: Free‐response receiver operating characteristic (FROC) analysis. Results: Our CAD system detected 94.2% (98/104) of aneurysms with 2.9 false positives per case (FPs/case). At a sensitivity of 70%, the number of FPs/case was 0.26. Data Conclusion: We showed that the combination of a CNN and an MIP algorithm is useful for the detection of intracranial aneurysms. Level of Evidence: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:948–953.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931
Hinton, G., Deng, L., Yu, D., Dahl, G., Mohamed, A.-R., Jaitly, N., Senior, A., Vanhoucke, V., Nguyen, P., Sainath, T., et al. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2205597 · Cited by 10,260
Automatic Detection of Cerebral Microbleeds From MR Images via 3D Convolutional Neural Networks
Dou, Q., Chen, H., Yu, L., Zhao, L., Qin, J., Wang, D., Mok, V. C., Shi, L., & Heng, P.-A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528129 · Cited by 679
Deep Feature Learning for Knee Cartilage Segmentation Using a Triplanar Convolutional Neural Network
Prasoon, A., Petersen, K., Igel, C., Lauze, F., Dam, E., & Nielsen, M. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40763-5_31 · Cited by 582
Computer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
Cited by
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Convolutional Neural Networks for Radiologic Images: A Radiologist’s Guide
Soffer, S., Ben-Cohen, A., Shimon, O., Amitai, M. M., Greenspan, H., & Klang, E. (2019) · Radiology · doi:10.1148/radiol.2018180547 · Cited by 511
Deep learning with convolutional neural network in radiology
Yasaka, K., Akai, H., Kunimatsu, A., Kiryu, S., & Abe, O. (2018) · Japanese Journal of Radiology · doi:10.1007/s11604-018-0726-3 · Cited by 368
Self-citationDeep learning enables reduced gadolinium dose for contrast-enhanced brain MRI
Gong, E., Pauly, J. M., Wintermark, M., & Zaharchuk, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25970 · Cited by 351
Deep learning and artificial intelligence in radiology: current applications and future directions
Yasaka, K., & Abe, O. (2018) · PLoS Medicine · doi:10.1371/journal.pmed.1002707 · Cited by 238
Metadata
- Authors
- Nakao, T., Hanaoka, S., Nomura, Y., Sato, I., Nemoto, M., Miki, S., Maeda, E., Yoshikawa, T., Hayashi, N., & Abe, O.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2017-08-24
- Volume
- 47
- Issue
- 4
- Pages
- 948-953
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2746587344
- Cited by
- 188
- References
- 6
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep neural network‐based computer‐assisted detection of cerebral aneurysms in MR angiography. https://app.cochat.ai/papers/10.1002/jmri.25842
- The paper
- Nakao, T., Hanaoka, S., Nomura, Y., Sato, I., Nemoto, M., Miki, S., Maeda, E., Yoshikawa, T., Hayashi, N., & Abe, O. (2018). Deep neural network‐based computer‐assisted detection of cerebral aneurysms in MR angiography. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.25842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.