CoChat

Fully Automated MR Detection and Segmentation of Brain Metastases in Non‐small Cell Lung Cancer Using Deep Learning

Open access
Jünger, Stephanie T., Hoyer, Ulrike Cornelia Isabel, Schaufler, Diana, Laukamp, Kai Roman, Goertz, Lukas, Thiele, Frank, Grunz, Jan‐Peter, Schlamann, Marc, Perkuhn, Michael, Kabbasch, Christoph, Persigehl, Thorsten, Grau, Stefan, Borggrefe, Jan, Scheffler, Matthias, Shahzad, Rahil, Pennig, Lenhard · 2021 · Journal of Magnetic Resonance Imaging
Cited by 48

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Non‐small cell lung cancer (NSCLC) is the most common tumor entity spreading to the brain and up to 50% of patients develop brain metastases (BMs). Detection of BMs on MRI is challenging with an inherent risk of missed diagnosis. Purpose: To train and evaluate a deep learning model (DLM) for fully automated detection and 3D segmentation of BMs in NSCLC on clinical routine MRI. Study Type: Retrospective. Population: Ninety‐eight NSCLC patients with 315 BMs on pretreatment MRI, divided into training (66 patients, 248 BMs) and independent test (17 patients, 67 BMs) and control (15 patients, 0 BMs) cohorts. Field Strength/Sequence: T 1‐/T 2‐weighted, T 1‐weighted contrast‐enhanced (T 1 CE; gradient‐echo and spin‐echo sequences), and FLAIR at 1.0, 1.5, and 3.0 T from various vendors and study centers. Assessment: A 3D convolutional neural network (DeepMedic) was trained on the training cohort using 5‐fold cross‐validation and evaluated on the independent test and control sets. Three‐dimensional voxel‐wise manual segmentations of BMs by a neurosurgeon and a radiologist on T 1 CE served as the reference standard. Statistical Tests: Sensitivity (recall) and false positive (FP) findings per scan, dice similarity coefficient (DSC) to compare the spatial overlap between manual and automated segmentations, Pearson's correlation coefficient (r) to evaluate the relationship between quantitative volumetric measurements of segmentations, and Wilcoxon rank‐sum test to compare the volumes of BMs. A P value <0.05 was considered statistically significant. Results: In the test set, the DLM detected 57 of the 67 BMs (mean volume: 0.99 ± 4.24 cm 3), resulting in a sensitivity of 85.1%, while FP findings of 1.5 per scan were observed. Missed BMs had a significantly smaller volume (0.05 ± 0.04 cm 3) than detected BMs (0.96 ± 2.4 cm 3). Compared with the reference standard, automated segmentations achieved a median DSC of 0.72 and a good volumetric correlation (r = 0.95). In the control set, 1.8 FPs/scan were observed. Data Conclusion: Deep learning provided a high detection sensitivity and good segmentation performance for BMs in NSCLC on heterogeneous scanner data while yielding a low number of FP findings. Level of Evidence: 3 Technical Efficacy Stage: 2

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.27741

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Jünger, S. T., Hoyer, U. C. I., Schaufler, D., Laukamp, K. R., Goertz, L., Thiele, F., Grunz, J., Schlamann, M., Perkuhn, M., Kabbasch, C., Persigehl, T., Grau, S., Borggrefe, J., Scheffler, M., Shahzad, R., & Pennig, L.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2021-05-25
Volume
54
Issue
5
Pages
1608-1622
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W3165130479
Cited by
48
References
6
FWCI
2.96
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.