Fully Automated MR Detection and Segmentation of Brain Metastases in Non‐small Cell Lung Cancer Using Deep Learning
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Non‐small cell lung cancer (NSCLC) is the most common tumor entity spreading to the brain and up to 50% of patients develop brain metastases (BMs). Detection of BMs on MRI is challenging with an inherent risk of missed diagnosis. Purpose: To train and evaluate a deep learning model (DLM) for fully automated detection and 3D segmentation of BMs in NSCLC on clinical routine MRI. Study Type: Retrospective. Population: Ninety‐eight NSCLC patients with 315 BMs on pretreatment MRI, divided into training (66 patients, 248 BMs) and independent test (17 patients, 67 BMs) and control (15 patients, 0 BMs) cohorts. Field Strength/Sequence: T 1‐/T 2‐weighted, T 1‐weighted contrast‐enhanced (T 1 CE; gradient‐echo and spin‐echo sequences), and FLAIR at 1.0, 1.5, and 3.0 T from various vendors and study centers. Assessment: A 3D convolutional neural network (DeepMedic) was trained on the training cohort using 5‐fold cross‐validation and evaluated on the independent test and control sets. Three‐dimensional voxel‐wise manual segmentations of BMs by a neurosurgeon and a radiologist on T 1 CE served as the reference standard. Statistical Tests: Sensitivity (recall) and false positive (FP) findings per scan, dice similarity coefficient (DSC) to compare the spatial overlap between manual and automated segmentations, Pearson's correlation coefficient (r) to evaluate the relationship between quantitative volumetric measurements of segmentations, and Wilcoxon rank‐sum test to compare the volumes of BMs. A P value <0.05 was considered statistically significant. Results: In the test set, the DLM detected 57 of the 67 BMs (mean volume: 0.99 ± 4.24 cm 3), resulting in a sensitivity of 85.1%, while FP findings of 1.5 per scan were observed. Missed BMs had a significantly smaller volume (0.05 ± 0.04 cm 3) than detected BMs (0.96 ± 2.4 cm 3). Compared with the reference standard, automated segmentations achieved a median DSC of 0.72 and a good volumetric correlation (r = 0.95). In the control set, 1.8 FPs/scan were observed. Data Conclusion: Deep learning provided a high detection sensitivity and good segmentation performance for BMs in NSCLC on heterogeneous scanner data while yielding a low number of FP findings. Level of Evidence: 3 Technical Efficacy Stage: 2
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient multi-scale 3D CNN with fully connected CRF for accurate brain lesion segmentation
Kamnitsas, K., Ledig, C., Newcombe, V. F. J., Simpson, J. P., Kane, A. D., Menon, D. K., Rueckert, D., & Glocker, B. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.10.004 · Cited by 3,498 · cited 1×
“The last prediction layer has a kernel size of 1(3) and employs sigmoid as the activation function.(22)”
BackgroundOsimertinib or Platinum–Pemetrexed in EGFR T790M–Positive Lung Cancer
Mok, T. S., Wu, Y.-L., Ahn, M.-J., Garassino, M. C., Kim, H. R., Ramalingam, S. S., Shepherd, F. A., He, Y., Akamatsu, H., Theelen, W. S. M. E., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1612674 · Cited by 3,379 · cited 3×
“37 At the same time, the survival rates have improved due to advances in anticancer treatments, 13 resulting in increased numbers of primary and follow-up imaging for assessment of BMs.”
BackgroundYamamoto, M., Serizawa, T., Shuto, T., Akabane, A., Higuchi, Y., Kawagishi, J., Yamanaka, K., Sato, Y., Jokura, H., Yomo, S., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70061-0 · Cited by 1,447 · cited 1×
“However, the exact assessment of the number of BMs is relevant because it guides the most suitable type of treatment, together with patient’s characteristics.(10) Automated detection of BMs could provide a preselection of lesions and facilitate the assessment of the extent of disease for radiologists and treating phys…”
BackgroundDeep learning for brain MRI segmentation: state of the art and future directions
Akkus, Z., Galimzianova, A., Hoogi, A., Rubin, D. L., & Erickson, B. J. (2017) · Journal of Digital Imaging · doi:10.1007/s10278-017-9983-4 · Cited by 1,129 · cited 3×
“7,15,19,26 In this context, the majority of recent studies investigating deep learning-based detection of BMs used homogenous imaging data, mostly a standardized protocol consisting of a distinct 3D T 1 CE sequence at a single institution for planning of radiosurgery, 25,29 – 31 which limits their…”
BackgroundGeneralized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776 · cited 1×
“To reduce the detection of FP findings, the segmentation results from each of the five DLMs were fused using a majority voting scheme.(34) To assess for FPs in BM negative cases, the fused DLM was additionally applied on the control set (n = 15 patients).”
MethodMazzara, G. P., Velthuizen, R. P., Pearlman, J. L., Greenberg, H. M., & Wagner, H. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.01.026 · Cited by 216 · cited 2×
“7,15,16 Further, manual segmentation bears the risk of - inter-and intra-reader variabilities, consequently reducing reproducibility and increasing inaccuracies, which may affect the treatment outcome.”
Background
Cited by
Heidari, A., Javaheri, D., Toumaj, S., Navimipour, N. J., Rezaei, M., & Unal, M. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102572 · Cited by 138
2.5D and 3D segmentation of brain metastases with deep learning on multinational MRI data
Ottesen, J. A., Yi, D., Tong, E., Iv, M., Latysheva, A., Saxhaug, C., Jacobsen, K. D., Helland, Å., Emblem, K. E., Rubin, D. L., et al. (2023) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.1056068 · Cited by 32
“Nonetheless, the number of false positives reported for the OUH cohort is among the lowest reported in literature at the time of writing (Zhou et al., 2020b; Hsu et al., 2021; Jünger et al., 2021; Pennig et al., 2021; Rudie et al., 2021).”
BackgroundPflüger, I., Wald, T., Isensee, F., Schell, M., Meredig, H., Schlamp, K., Bernhardt, D., Brugnara, G., Heußel, C. P., Debus, J., et al. (2022) · Neuro-Oncology Advances · doi:10.1093/noajnl/vdac138 · Cited by 31
Metadata
- Authors
- Jünger, S. T., Hoyer, U. C. I., Schaufler, D., Laukamp, K. R., Goertz, L., Thiele, F., Grunz, J., Schlamann, M., Perkuhn, M., Kabbasch, C., Persigehl, T., Grau, S., Borggrefe, J., Scheffler, M., Shahzad, R., & Pennig, L.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2021-05-25
- Volume
- 54
- Issue
- 5
- Pages
- 1608-1622
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W3165130479
- Cited by
- 48
- References
- 6
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.