CoChat

GC/MS analysis of [2H5]phenylalanine at very low enrichment: Measurement of protein synthesis in health and disease

Slater, Christine, Preston, Tom, McMillan, Donald C., Falconer, J. Stuart, Fearon, Kenneth C. H. · 1995 · Journal of Mass Spectrometry
Cited by 39

The DOI matches its Crossref record.

Abstract

A gas chromatographic/mass spectrometric (GC/MS) method has been developed for the precise and accurate analysis of high enrichment (1–10 mol.% excess) and very low enrichment (0.005–0.12 mol.% excess) 2 H 5‐labelled phenylalanine. Tracer enrichment in free phenylalanine was measured by GC/electron impact MS analysis of the tert‐butyldimethylsilyl (TBDMS) derivative. The measurement of very low tracer enrichment, typical of that found in protein hydrolysates, was accomplished by careful control of sample yield during preparation and analysis of the TBDMS derivative of purified β‐phenylethylamine, produced by enzymatic decarboxylation and solvent extraction. The new method was illustrated by measurement of albumin synthesis in healthy patients using a rapid protocol which showed good patient acceptability and was straightforward to manage in the clinical setting. The mean (SEM) albumin fractional synthetic rate was 9.54% (0.81%) per day, in agreement with previous studies that used more complex clinical protocols and analytical procedures. Use of the same derivative for analysis of amino acid precursor and protein samples facilitated consecutive analysis on the same instrument without interruption, permitting rapid feedback of results to the clinician and the possibility of using the method in intervention studies. The method should prove useful in the study of the synthetic rate of other proteins and mixed tissue protein, which will help our understanding and management of protein metabolism in health and disease. The possibility of extending the use of multiple‐atom tracers combined with GC/MS analysis to other substrate metabolism studies was identified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.1190300917

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 39

Metadata

Authors
Slater, C., Preston, T., McMillan, D. C., Falconer, J. S., & Fearon, K. C. H.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
1995-09
Volume
30
Issue
9
Pages
1325-1332
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2017712697
Cited by
39
References
0
FWCI
0.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: GC/MS analysis of [2H5]phenylalanine at very low enrichment: Measurement of protein synthesis in health and disease. https://app.cochat.ai/papers/10.1002/jms.1190300917
The paper
Slater, C., Preston, T., McMillan, D. C., Falconer, J. S., & Fearon, K. C. H. (1995). GC/MS analysis of [2H5]phenylalanine at very low enrichment: Measurement of protein synthesis in health and disease. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.1190300917

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.