Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record.

MassKinetics: a theoretical model of mass spectra incorporating physical processes, reaction kinetics and mathematical descriptions

Drahos, László, Vékey, Károly · 2001 · Journal of Mass Spectrometry

Abstract

A theoretical framework and an accompanying computer program (MassKinetics, www.chemres.hu/ms/ masskinetics) is developed for describing reaction kinetics under statistical, but non‐equilibrium, conditions, i.e. those applying to mass spectrometry. In this model all the important physical processes influencing product distributions are considered: reactions, including the effects of acceleration, collisions and photon exchange. These processes occur simultaneously and are taken into account by the master equation approach. The system is described by (independent) product, kinetic energy and internal energy distributions, and the time development of these distributions is studied using transition probability functions. The product distribution at the end of the experiment corresponds to the mass spectrum. Individual elements in this scheme are mostly well known: internal energy‐dependent reaction rates are calculated by transition state theory (RRK or RRKM formalisms). In the course of collisions, energy transfer and other processes may occur (the latter usually resulting in the ‘loss’ of ion signal). Collisions are characterized by their probability and by energy transfer in a single collision. To describe single collisions, three collision models are used: long‐lived collision complexes, partially inelastic collisions and partially inelastic collisions with cooling. The latter type has been developed here, and is capable of accounting for cooling effects occurring in collision cascades. Descriptions of photon absorption and emission are well known in principle, and these are also taken into account, in addition to changes in kinetic energy due to external (electric) fields. These changes in the system occur simultaneously, and are described by master equations (a set of differential equations). The usual form of the master equation (taking into account reactions and collisional excitation) was extended to consider also radiative energy transfer, kinetic energy changes, energy partitioning and ion loss collisions. Initial results show that close to experimental accuracy can be obtained with MassKinetics, using few or no adjustable parameters. The model/program can be used to model almost all types of mass spectrometric experiments (e.g. MIKE, CID, SORI and resonant excitation). Note that it was designed for mass spectrometric applications, but can also be used to study reaction kinetics in other non‐equilibrium systems. Copyright © 2001 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.142

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Drahos, L., & Vékey, K.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2001-03
Volume
36
Issue
3
Pages
237-263
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2106618903
Cited by
169
References
0
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.