The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Mass defect filter technique and its applications to drug metabolite identification by high‐resolution mass spectrometry
Abstract
Identification of drug metabolites by liquid chromatography/mass spectrometry (LC/MS) involves metabolite detection in biological matrixes and structural characterization based on product ion spectra. Traditionally, metabolite detection is accomplished primarily on the basis of predicted molecular masses or fragmentation patterns of metabolites using triple‐quadrupole and ion trap mass spectrometers. Recently, a novel mass defect filter (MDF) technique has been developed, which enables high‐resolution mass spectrometers to be utilized for detecting both predicted and unexpected drug metabolites based on narrow, well‐defined mass defect ranges for these metabolites. This is a new approach that is completely different from, but complementary to, traditional molecular mass‐ or MS/MS fragmentation‐based LC/MS approaches. This article reviews the mass defect patterns of various classes of drug metabolites and the basic principles of the MDF approach. Examples are given on the applications of the MDF technique to the detection of stable and chemically reactive metabolites in vitro and in vivo. Advantages, limitations, and future applications are also discussed on MDF and its combinations with other data mining techniques for the detection and identification of drug metabolites. Copyright © 2009 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Christopher, L. J., Cui, D., Li, W., Barros, A., Arora, V. K., Zhang, H., Wang, L., Zhang, D., Manning, J. A., He, K., et al. (2008) · Drug Metabolism and Disposition · doi:10.1124/dmd.107.018234 · Cited by 40
Self-citation
Cited by
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
The use of mass defect in modern mass spectrometry
Sleno, L. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.2953 · Cited by 283
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Klont, F., Kremer, D., Gomes Neto, A. W., Berger, S. P., Touw, D. J., Hak, E., Bonner, R., Bakker, S. J. L., & Hopfgartner, G. (2021) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2021.02.008 · Cited by 14
Metadata
- Authors
- Zhang, H., Zhang, D., Ray, K., & Zhu, M.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2009-07
- Volume
- 44
- Issue
- 7
- Pages
- 999-1016
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2028470385
- Cited by
- 294
- References
- 1
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass defect filter technique and its applications to drug metabolite identification by high‐resolution mass spectrometry. https://app.cochat.ai/papers/10.1002/jms.1610
- The paper
- Zhang, H., Zhang, D., Ray, K., & Zhu, M. (2009). Mass defect filter technique and its applications to drug metabolite identification by high‐resolution mass spectrometry. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.1610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.