Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes

Schuhmann, Kai, Almeida, Reinaldo, Baumert, Mark, Herzog, Ronny, Bornstein, Stefan R., Shevchenko, Andrej·2012·Journal of Mass Spectrometry

Abstract

Top–down shotgun lipidomics relies on direct infusion of total lipid extracts into a high‐resolution tandem mass spectrometer and implies that individual lipids are recognized by their accurately determined m/z. Lipid ionization efficiency and detection specificity strongly depend on the acquisition polarity, and therefore it is beneficial to analyze lipid mixtures in both positive and negative modes. Hybrid LTQ Orbitrap mass spectrometers are widely applied in top–down lipidomics; however, rapid polarity switching was previously unfeasible because of the severe and immediate degradation of mass accuracy. Here, we report on a method to rapidly acquire high‐resolution spectra in both polarity modes with sub‐ppm mass accuracy and demonstrate that it not only simplifies and accelerates shotgun lipidomics analyses but also improves the lipidome coverage because more lipid classes and more individual species within each class are recognized. In this way, shotgun analysis of total lipid extracts of human blood plasma enabled to quantify 222 species from 15 major lipid classes within 7 min acquisition cycle. Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.2031

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 207

Metadata

Authors
Schuhmann, K., Almeida, R., Baumert, M., Herzog, R., Bornstein, S. R., & Shevchenko, A.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2012-01
Volume
47
Issue
1
Pages
96-104
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W1569454591
Cited by
207
References
2
FWCI
9.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes. https://app.cochat.ai/papers/10.1002/jms.2031
The paper
Schuhmann, K., Almeida, R., Baumert, M., Herzog, R., Bornstein, S. R., & Shevchenko, A. (2012). Shotgun lipidomics on a LTQ Orbitrap mass spectrometer by successive switching between acquisition polarity modes. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.2031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.