Input resistance is voltage dependent due to activation of Ih channels in rat CA1 pyramidal cells
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The contribution of the hyperpolarization‐activated cation current (I h) to input resistance (R N) and resting potential (RP) was investigated during whole‐cell patch‐clamp recordings in CA1 pyramidal cells of rat hippocampal slices. In current‐clamp mode, R N was determined at different membrane potentials. R N decreased with increasing hyperpolarization, from about 260 MΩ to 140 MΩ at potentials of about −60 mV and −110 mV, respectively. Both the potential of half‐maximal reduction of R N and the potential of half‐maximal I h activation (determined in voltage‐clamp mode) were approximately −90 mV. The analysis of the voltage sag indicative of I h activation revealed a preferential activity of I h channels in a voltage range between −70 and −95 mV. ZD7288 (50 μM), a specific I h blocker, led to a hyperpolarization by about 4.8 mV, increased R N by approximately 45% within a potential range between −65 and −80 mV, and abolished the voltage dependence of R N. Gabapentin (GBP, 100 μM), an I h channel agonist, led to a depolarization by about 2.4 mV and reduced R N by about 20% within a potential range between −65 and −80 mV. In conclusion, our data show that R N is voltage dependent due to I h channel activation and that I h channels are preferentially active at voltages between −70 and −95 mV. Furthermore, we demonstrated that R N can be modulated by antiepileptic drugs such as GBP, which may partly explain its antiepileptic effect as due to decreasing the sensitivity to excitatory input. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magee, J. C. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-19-07613.1998 · Cited by 981
Dendritic Ih normalizes temporal summation in hippocampal CA1 neurons
Magee, J. C. (1999) · Nature Neuroscience · doi:10.1038/9158 · Cited by 617
Cited by
Gabapentin: a multimodal perioperative drug?
Kong, V. K. F., & Irwin, M. G. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem316 · Cited by 263
Ehrlich, D. E., Ryan, S. J., & Rainnie, D. G. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.237453 · Cited by 86
HCN Channel Targets for Novel Antidepressant Treatment
Ku, S. M., & Han, M.-H. (2017) · Neurotherapeutics · doi:10.1007/s13311-017-0538-7 · Cited by 54
Antidepressant-like activity of a brain penetrant HCN channel inhibitor in mice
Pinares-Garcia, P., Spyrou, J., McKenzie, C. E., Forster, I. C., Soh, M. S., Mohamed Syazwan, E., Atif, M., & Reid, C. A. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1159527 · Cited by 15
Metadata
- Authors
- Surges, R., Freiman, T. M., & Feuerstein, T. J.
- Venue
- Journal of Neuroscience Research
- Publisher
- Wiley
- Published
- 2004-03-29
- Volume
- 76
- Issue
- 4
- Pages
- 475-480
- ISSN
- 0360-4012 (ISSN-L)
- 1097-4547
- OpenAlex
- W2006205456
- Cited by
- 60
- References
- 2
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Input resistance is voltage dependent due to activation of Ih channels in rat CA1 pyramidal cells. https://app.cochat.ai/papers/10.1002/jnr.20075
- The paper
- Surges, R., Freiman, T. M., & Feuerstein, T. J. (2004). Input resistance is voltage dependent due to activation of Ih channels in rat CA1 pyramidal cells. Journal of Neuroscience Research. https://doi.org/10.1002/jnr.20075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.