Swelling of articular cartilage and other connective tissues: Electromechanochemical forces
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We have measured the relationship between tissue swelling stress and consolidation for bovine articular cartilage and corneal stroma in uniaxial confined compression as a function of bath ionic strength. Our experimental protocol and results clearly demonstrate that two concentration‐dependent material properties are necessary to describe the chemical dependence of tissue swelling stress in uniaxial compression over the range of deformations and concentrations explored. A general electromechanochemical model for the swelling stress of charged connective tissues is developed. The model focuses on the role of charged matrix macromolecules in determining the mechanical behavior of the tissue. A constitutive relation for the swelling stress in uniaxial confined compression in formulated and the concentration dependence of the material properties of articular cartilage and corneal stroma is determined. The associated free swelling behavior of cartilage and cornea specimens is computed from these results and is found to compare favorably with data from the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Principles of Polymer Chemistry.
Huggins, M. L. (1954) · Journal of the American Chemical Society · doi:10.1021/ja01639a090 · Cited by 16,550
Principles of polymer chemistry
(1995) · Choice Reviews Online · doi:10.5860/choice.33-2140 · Cited by 15,218
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Balance between swelling pressure and collagen tension in normal and degenerate cartilage
MAROUDAS, A. (1976) · Nature · doi:10.1038/260808a0 · Cited by 726
Wainwright, D. (1974) · Injury · doi:10.1016/0020-1383(74)90182-x · Cited by 511
McDevitt, C. A., & Muir, H. (1976) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.58b1.131804 · Cited by 444
Biophysical chemistry of cartilaginous tissues with special reference to solute and fluid transport1
Maroudas, A. (1975) · Biorheology · doi:10.3233/bir-1975-123-416 · Cited by 380
Electromechanical and physicochemical properties of connective tissue.
Grodzinsky, A. J. (1983) · PubMed · Cited by 247
Self-citation(2020) · Springer eBooks · doi:10.1007/978-981-15-2063-1 · Cited by 243
Cited by
Fluorometric assay of DNA in cartilage explants using Hoechst 33258
Kim, Y.-J., Sah, R. L. Y., Doong, J.-Y. H., & Grodzinsky, A. J. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90532-5 · Cited by 1,357
Self-citationKisiday, J., Jin, M., Kurz, B., Hung, H., Semino, C., Zhang, S., & Grodzinsky, A. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.142309999 · Cited by 1,045
Self-citationVunjak‐Novakovic, G., Martin, I., Obradovic, B., Treppo, S., Grodzinsky, A. J., Langer, R., & Freed, L. E. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170119 · Cited by 743
Self-citationScarcelli, G., Polacheck, W. J., Nia, H. T., Patel, K., Grodzinsky, A. J., Kamm, R. D., & Yun, S. H. (2015) · Nature Methods · doi:10.1038/nmeth.3616 · Cited by 432
Self-citationSetton, L. A., Elliott, D. M., & Mow, V. C. (1999) · Osteoarthritis and Cartilage · doi:10.1053/joca.1998.0170 · Cited by 378
A Molecular Model of Proteoglycan-Associated Electrostatic Forces in Cartilage Mechanics
Buschmann, M. D., & Grodzinsky, A. J. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2796000 · Cited by 331
Self-citationSoltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Setton, L. A., Zhu, W., & Mow, V. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90019-b · Cited by 316
Frank, E. H., & Grodzinsky, A. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90282-x · Cited by 301
Self-citationOcular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Frank, E. H., & Grodzinsky, A. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90283-1 · Cited by 283
Self-citationGu, W. Y., Lai, W. M., & Mow, V. C. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2798299 · Cited by 270
Cavalcante, F. S. A., Ito, S., Brewer, K., Sakai, H., Alencar, A. M., Almeida, M. P., Andrade, J. S., Majumdar, A., Ingenito, E. P., & Suki, B. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00619.2004 · Cited by 262
Biomechanical properties of knee articular cartilage
Laasanen, M. S., Töyräs, J., Korhonen, R. K., Rieppo, J., Saarakkala, S., Nieminen, M. T., Hirvonen, J., & Jurvelin, J. S. (2003) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2003040001003020 · Cited by 212
“Glycosaminoglycans (GAGs) attract water and repel each other due to their electronegativity, creating a swelling pressure that is restrained by the collagenous meshwork [5–8,26,38,40,41].”
Chimich, D., Shrive, N., Frank, C., Marchuk, L., & Bray, R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90223-n · Cited by 169
Metadata
- Authors
- Eisenberg, S. R., & Grodzinsky, A. J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 3
- Issue
- 2
- Pages
- 148-159
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2095964234
- Cited by
- 251
- References
- 21
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.