The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
A Conewise Linear Elasticity Mixture Model for the Analysis of Tension-Compression Nonlinearity in Articular Cartilage
Open accessAbstract
A biphasic mixture model is developed that can account for the observed tension-compression nonlinearity of cartilage by employing the continuum-based Conewise Linear Elasticity (CLE) model of Curnier et al. (J. Elasticity, 37, 1–38, 1995) to describe the solid phase of the mixture. In this first investigation, the orthotropic octantwise linear elasticity model was reduced to the more specialized case of cubic symmetry, to reduce the number of elastic constants from twelve to four. Confined and unconfined compression stress-relaxation, and torsional shear testing were performed on each of nine bovine humeral head articular cartilage cylindrical plugs from 6 month old calves. Using the CLE model with cubic symmetry, the aggregate modulus in compression and axial permeability were obtained from confined compression (H−A=0.64±0.22 MPa, kz=3.62±0.97×10−16 m4/Ns˙s,r2=0.95±0.03), the tensile modulus, compressive Poisson ratio, and radial permeability were obtained from unconfined compression (E+Y=12.75±1.56 MPa, v−=0.03±0.01,kr=6.06±2.10×10−16 m4/Ns˙s,r2=0.99±0.00), and the shear modulus was obtained from torsional shear (μ=0.17±0.06 MPa). The model was also employed to predict the interstitial fluid pressure successfully at the center of the cartilage plug in unconfined compression r2=0.98±0.01. The results of this study demonstrate that the integration of the CLE model with the biphasic mixture theory can provide a model of cartilage that can successfully curve-fit three distinct testing configurations while producing material parameters consistent with previous reports in the literature. [S0148-0731(00)00306-X]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
A Triphasic Theory for the Swelling and Deformation Behaviors of Articular Cartilage
Lai, W. M., Hou, J. S., & Mow, V. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894880 · Cited by 1,127
Kvålseth, T. O. (1985) · The American Statistician · doi:10.1080/00031305.1985.10479448 · Cited by 990
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage
Athanasiou, K. A., Rosenwasser, M. P., Buckwalter, J. A., Malinin, T. I., & Mow, V. C. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090304 · Cited by 750
Constitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
The frictional properties of animal joints
McCutchen, C. W. (1962) · Wear · doi:10.1016/0043-1648(62)90176-x · Cited by 640
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
Biphasic indentation of articular cartilage—II. A numerical algorithm and an experimental study
Mow, V. C., Gibbs, M. C., Lai, W. M., Zhu, W. B., & Athanasiou, K. A. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90069-9 · Cited by 509
Cited by
Korhonen, R. K., Laasanen, M. S., Töyräs, J., Rieppo, J., Hirvonen, J., Helminen, H. J., & Jurvelin, J. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00052-0 · Cited by 464
Li, W.-J., Mauck, R. L., Cooper, J. A., Yuan, X., & Tuan, R. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.004 · Cited by 400
Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication
Krishnan, R., Kopacz, M., & Ateshian, G. A. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.07.002 · Cited by 327
Self-citationMauck, R. L., Wang, C. C.-B., Oswald, E. S., Ateshian, G. A., & Hung, C. T. (2003) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2003.08.006 · Cited by 310
Self-citationCaligaris, M., & Ateshian, G. A. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.02.020 · Cited by 288
Self-citation
Metadata
- Authors
- Soltz, M. A., & Ateshian, G. A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2000-07-10
- Volume
- 122
- Issue
- 6
- Pages
- 576-586
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2033524895
- Cited by
- 330
- References
- 42
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Conewise Linear Elasticity Mixture Model for the Analysis of Tension-Compression Nonlinearity in Articular Cartilage. https://app.cochat.ai/papers/10.1115/1.1324669
- The paper
- Soltz, M. A., & Ateshian, G. A. (2000). A Conewise Linear Elasticity Mixture Model for the Analysis of Tension-Compression Nonlinearity in Articular Cartilage. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1324669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.