To evaluate pin/screw/plate fixation for management of femoral neck fractures, 39 proximal femora were tested in both torsion and flexion under physiological loading conditions. Three, four, or five implants of six commonly used multiple‐fixation devices, and a sliding hip screw with and without an additional 6.5‐mm cancellous screw were examined in paired femora. The intact and postfixation femora were initially subjected to a single applied moment, and the torsion and bending stiffness were determined from the load‐deformation data. Postfixation femora were also subjected to cyclic loading in flexion at three load ranges, and fixation was judged successful if no failure occurred on or before 1,500 cycles of 667 to 2,000 N of a combined compressive force and moment. Anterior‐posterior and lateral radiographs of each specimen were taken after fixation in order to evaluate Singh's index of bone density, fracture reduction, implant placement, and cross‐sectional diameter of the femoral neck. Bone density was also evaluated by computed tomography (CT) and physical measurement of core samples obtained from the femoral head. The results indicate that there appears to be no justification for the use of more than three pin/screw implants for management of femoral neck fractures. Bone density was found to correlate with fracture stability and may be a useful predictor of fixation success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Cited by
Factors Affecting the Pullout Strength of Cancellous Bone Screws
Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., & Kowalski, D. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796022 · Cited by 503
Self-citationFracture healing in osteoporotic fractures: Is it really different?
Giannoudis, P., Tzioupis, C., Almalki, T., & Buckley, R. (2007) · Injury · doi:10.1016/j.injury.2007.02.014 · Cited by 272
Metadata
- Authors
- Swiontkowski, M. F., Harrington, R. M., Keller, T. S., & Van Patten, P. K.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 5
- Issue
- 3
- Pages
- 433-444
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2038515586
- Cited by
- 167
- References
- 1
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Torsion and bending analysis of internal fixation techniques for femoral neck fractures: The role of implant design and bone density. https://app.cochat.ai/papers/10.1002/jor.1100050316
- The paper
- Swiontkowski, M. F., Harrington, R. M., Keller, T. S., & Van Patten, P. K. (1987). Torsion and bending analysis of internal fixation techniques for femoral neck fractures: The role of implant design and bone density. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100050316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.