Factors Affecting the Pullout Strength of Cancellous Bone Screws
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Screws placed into cancellous bone in orthopedic surgical applications, such as fixation of fractures of the femoral neck or the lumbar spine, can be subjected to high loads. Screw pullout is a possibility, especially if low density osteoporotic bone is encountered. The overall goal of this study was to determine how screw thread geometry, tapping, and cannulation affect the holding power of screws in cancellous bone and determine whether current designs achieve maximum purchase strength. Twelve types of commercially available cannulated and noncannulated cancellous bone screws were tested for pullout strength in rigid unicellular polyurethane foams of apparent densities and shear strengths within the range reported for human cancellous bone. The experimentally derived pullout strength was compared to a predicted shear failure force of the internal threads formed in the polyurethane foam. Screws embedded in porous materials pullout by shearing the internal threads in the porous material. Experimental pullout force was highly correlated to the predicted shear failure force (slope = 1.05, R2 = 0.947) demonstrating that it is controlled by the major diameter of the screw, the length of engagement of the thread, the shear strength of the material into which the screw is embedded, and a thread shape factor (TSF) which accounts for screw thread depth and pitch. The average TSF for cannulated screws was 17 percent lower than that of noncannulated cancellous screws, and the pullout force was correspondingly less. Increasing the TSF, a result of decreasing thread pitch or increasing thread depth, increases screw purchase strength in porous materials. Tapping was found to reduce pullout force by an average of 8 percent compared with nontapped holes (p = 0.0001). Tapping in porous materials decreases screw pullout strength because the removal of material by the tap enlarges hole volume by an average of 27 percent, in effect decreasing the depth and shear area of the internal threads in the porous material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Swiontkowski, M. F., Harrington, R. M., Keller, T. S., & Van Patten, P. K. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050316 · Cited by 167
Self-citationMultiaxial strength characteristics of trabecular bone
Stone, J. L., Beaupré, G. S., & Hayes, W. C. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90083-0 · Cited by 133
Design and testing of external fixator bone screws
Evans, M., Spencer, M., Wang, Q., White, S. H., & Cunningham, J. L. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90054-q · Cited by 60
Cited by
The orthopaedic treatment of fragility fractures.
(2007) · PubMed Central · Cited by 43
Metadata
- Authors
- Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., & Kowalski, D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1996-08-01
- Volume
- 118
- Issue
- 3
- Pages
- 391-398
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2160855647
- Cited by
- 503
- References
- 4
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors Affecting the Pullout Strength of Cancellous Bone Screws. https://app.cochat.ai/papers/10.1115/1.2796022
- The paper
- Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., & Kowalski, D. (1996). Factors Affecting the Pullout Strength of Cancellous Bone Screws. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2796022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.