Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

Anterior cruciate ligament replacements: A mechanical study of femoral attachment location, flexion angle at tensioning, and initial tension

Bylski‐Austrow, D. I., Grood, E. S., Hefzy, M. S., Holden, J. P., Butler, D. L.·1990·Journal of Orthopaedic Research

Abstract

We examined three surgical variables that affect the ability of an anteior cruciate ligament replacement to restore the limit of anterior tibial translation. These were the placement site of the substitute on the femur, the initial tension applied to the replacement, and the flexion angle of the knee at the time of tensioning. An anterior load of 100 N was applied to the tibia. As the knee was flexed, we measured the tensile force in the substitute and the anteroposterior position of the femur relative to the tibia. Placement largely determined whether the force in the replacement increased or decreased with flexion. Placement also largely determined whether the tibia moved anteriorly or posteriorly with flexion compared to its position in the intact knee. The initial tension and the flexion angle at tensioning affected the magnitude of force in the substitute and the magnitude of the change in AP position. They did not affect how force and AP position changed with flexion. Greater increases in force and greater posterior shifts in tibial position were produced by changing the flexion angle at tensioning from 0° to 30° than by increasing the initial tension from 22 to 44 N.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100080408

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Bylski‐Austrow, D. I., Grood, E. S., Hefzy, M. S., Holden, J. P., & Butler, D. L.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1990-07
Volume
8
Issue
4
Pages
522-531
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2122592912
Cited by
198
References
0
FWCI
6.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anterior cruciate ligament replacements: A mechanical study of femoral attachment location, flexion angle at tensioning, and initial tension. https://app.cochat.ai/papers/10.1002/jor.1100080408
The paper
Bylski‐Austrow, D. I., Grood, E. S., Hefzy, M. S., Holden, J. P., & Butler, D. L. (1990). Anterior cruciate ligament replacements: A mechanical study of femoral attachment location, flexion angle at tensioning, and initial tension. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100080408

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.