The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of gamma irradiation on the initial mechanical and material properties of goat bone‐patellar tendon‐bone allografts
Abstract
The effects of 60 Co gamma irradiation on the initial mechanical properties of the composite bone‐patellar tendon‐bone unit (CU) and the tendon midsubstance (TM) were studied. Frozen specimens were exposed to either 2 or 3 Mrad of gamma irradiation. Paired frozen specimens served as intraanimal controls. Treatment effects on the CU were assessed using four mechanical parameters. Effects on the TM were assessed using four material parameters measured using an optical surface‐strain analysis system. The maximum force and strain energy to maximum force of the composite unit were significantly reduced 27% and 40%, respectively, after 3 Mrad of irradiation (p < .05). Mechanical properties of the CU were not significantly altered, however, following 2 Mrad of irradiation. Based on individual paired contrasts between treatment and control, significant differences were also found in the material properties of the tendon midsubstance. The maximum stress, maximum strain, and strain energy density to maximum stress were significantly reduced following 3 Mrad, but not 2 Mrad, of irradiation. The results provide important “time zero” material property data, which will be useful for later anterior cruciate ligament reconstruction studies using irradiated allograft patellar tendons in the goat model and other animal models as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ballock, R. T., Woo, S. L., Lyon, R. M., Hollis, J. M., & Akeson, W. H. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070404 · Cited by 230
Cited by
Current Concepts Review - The Science of Reconstruction of the Anterior Cruciate Ligament*
FRANK, C. B., & JACKSON, D. W. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199710000-00014 · Cited by 622
Revision Anterior Cruciate Ligament Reconstruction Surgery
Getelman, M. H., & Friedman, M. J. (1999) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-199905000-00005 · Cited by 295
Sterilization of allograft bone: effects of gamma irradiation on allograft biology and biomechanics
Nguyen, H., Morgan, D. A. F., & Forwood, M. R. (2007) · Cell and Tissue Banking · doi:10.1007/s10561-006-9020-1 · Cited by 257
Sun, W. Q., & Leung, P. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.006 · Cited by 114
Metadata
- Authors
- Gibbons, M. J., Butler, D. L., Grood, E. S., Bylski‐Austrow, D. I., Levy, M. S., & Noyes, F. R.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-03
- Volume
- 9
- Issue
- 2
- Pages
- 209-218
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2149449617
- Cited by
- 205
- References
- 1
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of gamma irradiation on the initial mechanical and material properties of goat bone‐patellar tendon‐bone allografts. https://app.cochat.ai/papers/10.1002/jor.1100090209
- The paper
- Gibbons, M. J., Butler, D. L., Grood, E. S., Bylski‐Austrow, D. I., Levy, M. S., & Noyes, F. R. (1991). Effects of gamma irradiation on the initial mechanical and material properties of goat bone‐patellar tendon‐bone allografts. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100090209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.