Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Lack of initial mechanical stability of cementless prostheses may be responsible for fibrous tissue fixation of prosthetic components to bone. To study the influence of micromovements on bony ingrowth into titanium alloy (Ti) and hydroxyapatite (HA)‐coated implants, a loaded unstable device producing movements of 500 μm during each gait cycle was developed. Mechanically stable implants served as controls. The implants were inserted into the weight‐bearing regions of all four femoral condyles in each of seven mature dogs. Histological analysis after 4 weeks of implantation showed a fibrous tissue membrane surrounding both Ti and HA‐coated implants subjected to micromovements, whereas variable amounts of bony ingrowth were obtained in mechanically stable implants. The pushout test showed that the shear strength of unstable Ti and HA implants was significantly reduced as compared with the corresponding mechanically stable implants (p < 0.01). However, shear strength values of unstable HA‐coated implants were significantly greater than those of unstable Ti implants (p < 0.01) and comparable to those of stable Ti implants. The greatest shear strength was obtained with stable HA‐coated implants, which was threefold stronger as compared with the stable Ti implants (p < 0.001). Quantitative determination of bony ingrowth agreed with the mechanical test except for the stronger anchorage of unstable HA implants as compared with unstable Ti implants, where no difference in bony ingrowth was found. Unstable HA‐coated implants were surrounded by a fibrous membrane containing islands of fibrocartilage with higher collagen concentration, whereas fibrous connective tissue with lower collagen concentration was predominant around unstable Ti implants. In conclusion, micromovements between bone and implant inhibited bony ingrowth and led to the development of a fibrous membrane. The presence of fibrocartilage and a higher collagen concentration in the fibrous membrane may be responsible for the increased shear strength of unstable HA implants. Mechanically stable implants with HA coating had the strongest anchorage and the greatest amount of bony ingrowth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone histomorphometry : techniques and interpretation
Recker, R. R. (1983) · CRC Press eBooks · Cited by 1,158
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
THE DETERMINATION OF COLLAGEN AND ELASTIN IN TISSUES
Neuman, R. E., & Logan, M. A. (1950) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)56248-7 · Cited by 817
BASSETT, C. A. L., & HERRMANN, I. (1961) · Nature · doi:10.1038/190460a0 · Cited by 263
Søballe, K., Hansen, E. S., Brockstedt-Rasmussen, H., Pedersen, C. M., & Bünger, C. (1990) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679008993521 · Cited by 197
Self-citationImplant fixation improved by close fit Cylindrical implant – bone interface studied in rabbits
Carlsson, L., Röstlund, T., Albrektsson, B., & Albrektsson, T. (1988) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678809149361 · Cited by 195
Bioreactions at the tissue/ hydroxyapatite interface
van Blitterswijk, C. A., Grote, J. J., Kuÿpers, W., Blok-van Hoek, C. J. G., & Daems, W. T. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90020-1 · Cited by 174
Jackson, D. S. (1977) · FEBS Letters · doi:10.1016/0014-5793(77)80502-4 · Cited by 172
Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured Implants
Pilliar, R. M., Cameron, H. U., WELSH, R. P., & Binnington, A. G. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198105000-00037 · Cited by 129
Characteristics of tissue growth into proplast and porous polyethylene implants in bone
Spector, M., Harmon, S. L., & Kreutner, A. (1979) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820130502 · Cited by 102
Micromotion in knee arthroplasty
Ryd, L. (1986) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678609157924 · Cited by 85
Ashhurst, D. E. (1986) · Philosophical transactions of the Royal Society of London. Series B, Biological sciences · doi:10.1098/rstb.1986.0038 · Cited by 75
Cited by
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1056 · Cited by 1,065
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Biophysical stimuli on cells during tissue differentiation at implant interfaces
Prendergast, P. J., Huiskes, R., & Søballe, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00140-6 · Cited by 634
Self-citationAseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Ratnayake, J. T. B., Mucalo, M., & Dias, G. J. (2017) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33651 · Cited by 364
Metadata
- Authors
- Søballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 10
- Issue
- 2
- Pages
- 285-299
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2059325835
- Cited by
- 506
- References
- 12
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.