CoChat
Cited by 213

The DOI matches its Crossref record.

Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty

Cheal, Edward J., Spector, Myron, Hayes, Wilson C. · 1992 · Journal of Orthopaedic Research

Abstract

The objective of this study was to establish the role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. We developed a three‐dimensional finite element model of an intact human femur and the same femur with a conventional collared straight‐stem femoral component. Using published data, we defined two sets of loading conditions: one that represented three phases of gait, and one that represented four different extreme loads. The four extreme loads were based on the peak joint contact forces that occur during stair ascent and isometric contraction of various muscle groups. The model was analyzed with three different material properties for the prosthesis, including cobalt‐chromium alloy, titanium alloy, and a carbon fiber‐reinforced polymer (CFRP) laminate. We assumed that the implant was stable, with rigid bonding, collar contact, and no cement. To address femoral component loosening, we examined the shear stresses at the implant‐bone interface; to address adaptive bone remodeling, we examined the principal stresses in the supporting cortical bone relative to those in the intact femur. Our analyses of the various loading conditions demonstrated large out‐of‐plane bending moments and torsional moments, especially for the load representing stair ascent. Based on stepwise multiple regressions, the maximum shear stresses at the implant‐bone interface in the distal region were dependent on the total applied axial force and torsion; the maximum shear stresses in the proximal region were dependent on the axial component of the joint contact force alone. Reduction in the prosthesis stiffness, by substitution of the CFRP material properties, resulted in lower interface shear stresses at the distal end of the stem and higher interface shear stresses at the more proximal sections, consistent with the findings of others. We fit equations, based on composite beam theory, to the maximum implant‐bone interface shear stresses and the cortical bone principal stresses as a function of the axial modulus of the prosthesis. These equations can be used to estimate the maximum stresses at the interface and in the cortical bone that would be predicted by similar models, for the same prosthesis constructed of alternative materials, relative to the stresses in the intact femur. The nonlinear nature of these relationships was such that the cortical bone stresses changed more rapidly, as a function of the prosthesis modulus, for lower values of elastic modulus, especially in the more proximal sections.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100100314

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cheal, E. J., Spector, M., & Hayes, W. C.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1992-05
Volume
10
Issue
3
Pages
405-422
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2090138864
Cited by
213
References
0
FWCI
5.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.