The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Stress and strain distribution within the intact femur: compression or bending?
Abstract
The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite element analysis of the intact femur to assess if a compressive stress distribution could be achieved in the diaphyseal region of the femur using physiological muscle and joint contact forces; a simple radiological study to assess the in vivo deflections of the femur during one legged stance. The results of this investigation strongly support the hypothesis that the femur is loaded primarily in compression, and not bending as previously thought. The finite element analysis demonstrated that a compressive stress distribution in the diaphyseal femur can be achieved, producing a stress distribution which appears to be consistent with the femoral cross-sectional geometry. The finite element analysis also predicted that for a compressive load case there would be negligible deflections of the femoral head. The radiological study confirmed this, with no measurable in vivo deflection of the femur occurring during one legged stance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hip joint loading during walking and running, measured in two patients
Bergmann, G., Graichen, F., & Rohlmann, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90058-m · Cited by 1,276
Wolff, J. (1986) · Springer eBooks · doi:10.1007/978-3-642-71031-5 · Cited by 802
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Pauwels, F. (1980) · Springer eBooks · doi:10.1007/978-3-642-67138-8 · Cited by 643
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 499
Bone Deformation Recorded in vivo from Strain Gauges Attached to the Human Tibial Shaft
Lanyon, L. E., Hampson, W. G. J., Goodship, A. E., & Shah, J. S. (1975) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677508989216 · Cited by 475
A biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448
Telemetric force measurements across the hip after total arthroplasty.
Davy, D. T., Kotzar, G. M., Brown, R. H., Heiple, K. G., Goldberg, V. M., Heiple, K. G., Berilla, J., & Burstein, A. H. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870010-00008 · Cited by 416
Foeces transmitted by joints in the human body
Poul, J. (1967) · Cited by 334
Cited by
Crime prevention through environmental design (CPTED): a review and modern bibliography
Cozens, P. M., Saville, G., & Hillier, D. (2005) · Property Management · doi:10.1108/02637470510631483 · Cited by 684
Metadata
- Authors
- Taylor, M. E., Tanner, K. E., Freeman, M. A. R., & Yettram, A. L.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1996-03-01
- Volume
- 18
- Issue
- 2
- Pages
- 122-131
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2109310956
- Cited by
- 263
- References
- 15
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stress and strain distribution within the intact femur: compression or bending? https://app.cochat.ai/papers/10.1016/1350-4533(95)00031-3
- The paper
- Taylor, M. E., Tanner, K. E., Freeman, M. A. R., & Yettram, A. L. (1996). Stress and strain distribution within the intact femur: compression or bending? Medical Engineering & Physics. https://doi.org/10.1016/1350-4533(95)00031-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.