CoChat
Cited by 182

The DOI matches its Crossref record.

In vivo inflammatory response to polymethylmethacrylate particulate debris: Effect of size, morphology, and surface area

Gelb, Howard, Ralph Schumacher, H., Cuckler, John, Baker, Daniel G. · 1994 · Journal of Orthopaedic Research

Abstract

Particulate debris, including that from polymethylmethacrylate (PMMA) cement, is observed commonly in the membrane surrounding loose joint prostheses. Such debris is assumed to cause an inflammatory response and contributes to osteolysis and failure of the implant. A subcutaneous rat air‐pouch model was used to assess quantitatively the in vivo effects of the size, morphology, and surface area of PMMA particles on the acute inflammatory response. PMMA particles were divided into three groups. In Group A, mechanical grinding of cured bone cement produced irregularly shaped particles; Group B included spherical particles of PMMA powder (Simplex P); and Group C consisted of commercially prepared spherical latex particles. All three groups had two size distributions: < 20 μm and 50–350 μm. For a given mass or dose, the small, irregularly shaped mechanically produced particles in Group A elicited a significantly greater inflammatory reaction than the large particles in Group A, as expressed by the release of tumor necrosis factor (TNF), neutral metalloprotease (NMP), and prostaglandin E 2 (PGE 2) and the white blood cell (WBC) count within a 24‐hour period. Similar findings were seen in Group B. Particles in Group C were used to compare the effect of absolute numbers of large and small particles and surface area. Large (10–126 μm) spherical PMMA particles at a dose of 1.7 × 10 6 particles/ml caused a significantly higher inflammatory response, as measured by WBC count and production of NMP and PGE 2, than small (1–10 μm) spheres at a dose of 4 × 10 6 particles/ml. However, the production of TNF in the rats was significantly increased with small particles (p < 0.05) at a concentration 4‐fold less than that with the large particles (4 × 10 5 compared with 1.7 × 10 6 particles/ml). This finding may reflect a different cellular mechanism for the TNF component of the inflammatory response than is measured by WBC counts or by levels of PGE 2 and NMP. As the calculated surface area of the PMMA particles increased, a threshold level was reached, at which point the inflammatory response increased dramatically. The size of particles has a role in the prolongation and intensity of the release of specific cytokines. The total surface area of the particles appeared to be an important factor in determining the inflammatory response, as measured by WBC count, PGE 2, TNF, and NMP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100120111

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Gelb, H., Ralph Schumacher, H., Cuckler, J., & Baker, D. G.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1994-01
Volume
12
Issue
1
Pages
83-92
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2034118909
Cited by
182
References
0
FWCI
8.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.