Chondrocyte cells respond mechanically to compressive loads
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Many studies have illustrated the effect of mechanical loading on articular cartilage and the corresponding changes in chondrocyte metabolism, yet the mechanism through which the cells respond to loading still is unclear. The purpose of this study was to evaluate the change in shape of chondrocytes under a statically applied uniaxial compressive load. Isolated chondrocytes from rat chondrosarcoma were embedded in 2% agarose gel. Strains of 5, 10, and 15% were applied, and images of the cell were recorded from initial loading to equilibrium (15 minutes). A finite‐element model was used to model the experimental setup and to estimate the mechanical properties of the chondrocyte at equilibrium. The transient behavior of the composite in the experiment was analyzed with use of a standard linear viscoelastic model. We found that all cells decreased in cross‐sectional area under each of the applied compressive strains. In the finite‐element model, the elasticity of the chondrocyte was similar to that of the surrounding agarose gel (4.0 kPa) and had a Poisson's ratio of 0.4. Viscoelastic analysis showed that the chondrocytes contributed a significant viscoelastic component to the behavior of the composite in comparison with the agarose gel alone. If a decrease in cell volume proportional to the decrease in cross‐sectional area is assumed, the decrease observed was greater than would be predicted by a passive cellular response due to an equivalent osmotic pressure. This indicates that the chondrocyte may be altering its intracellular composition by cellular processes in response to mechanical loading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The finite element method in engineering science
Zienkiewicz, O. C. (1971) · CERN Document Server (European Organization for Nuclear Research) · Cited by 4,376
Biosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875
Review of Physiological Chemistry
(1964) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1964.tb114211.x · Cited by 727
A First Course in Continuum Mechanics
Gonzalez, O., & Stuart, A. M. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511619571 · Cited by 601
A first course in continuum mechanics
Fung, Y. C. (1969) · Medical Entomology and Zoology · Cited by 550
Articular Cartilage Biochemistry
(1987) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(87)90023-2 · Cited by 496
Mechanical and physicochemical determinants of the chondrocyte biosynthetic response
Gray, M. L., Pizzanelli, A. M., Grodzinsky, A. J., & Lee, R. C. (1988) · Journal of Orthopaedic Research · doi:10.1002/jor.1100060602 · Cited by 429
Function follows form: generation of intracellular signals by cell deformation
Watson, P. A. (1991) · The FASEB Journal · doi:10.1096/fasebj.5.7.1707019 · Cited by 346
The effects of hydrostatic pressure on matrix synthesis in articular cartilage
Hall, A. C., Urban, J. P. G., & Gehl, K. A. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090102 · Cited by 330
Effects of static and cyclic compressive loading on articular cartilage plugs in vitro
Palmoski, M. J., & Brandt, K. D. (1984) · Arthritis & Rheumatism · doi:10.1002/art.1780270611 · Cited by 265
Articular Cartilage and Osteoarthritis
Doherty, M. (1992) · Annals of the Rheumatic Diseases · doi:10.1136/ard.51.9.1028-a · Cited by 232
Schneiderman, R., Keret, D., & Maroudas, A. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040402 · Cited by 198
Cartilage response to mechanical force in high‐density chondrocyte cultures
Kampen, G. P. J. V., Veldhuijzen, J. P., Kuijer, R., van de Stadt, R. J., & Schipper, C. A. (1985) · Arthritis & Rheumatism · doi:10.1002/art.1780280410 · Cited by 121
Sun, D., Aydelotte, M. B., Maldonado, B., Kuettner, K. E., & Kimura, J. H. (1986) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100040405 · Cited by 49
Self-citation
Cited by
Mechanobiology of Skeletal Regeneration
Carter, D. R., Beaupr??, G. S., Giori, N. J., & Helms, J. A. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00006 · Cited by 758
Mechanical compression modulates matrix biosynthesis in chondrocyte/agarose culture
Buschmann, M. D., Gluzband, Y. A., Grodzinsky, A. J., & Hunziker, E. B. (1995) · Journal of Cell Science · doi:10.1242/jcs.108.4.1497 · Cited by 744
Cartilage Tissue Remodeling in Response to Mechanical Forces
Grodzinsky, A. J., Levenston, M. E., Jin, M., & Frank, E. H. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.691 · Cited by 642
Emerging views of the nucleus as a cellular mechanosensor
Kirby, T. J., & Lammerding, J. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0038-y · Cited by 564
Techniques for mechanical stimulation of cells in vitro: a review
Brown, T. D. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00177-3 · Cited by 539
Metadata
- Authors
- Freeman, P. M., Natarajan, R. N., Kimura, J. H., & Andriacchi, T. P.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1994-05
- Volume
- 12
- Issue
- 3
- Pages
- 311-320
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048396738
- Cited by
- 195
- References
- 15
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.