Human monocyte/macrophage response to cobalt‐chromium corrosion products and titanium particles in patients with total joint replacements

Lee, S‐H., Brennan, F. R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., Glant, T. T. · 1997 · Journal of Orthopaedic Research

Abstract

The responses of human peripheral blood monocytes of 10 normal volounteers and 14 patients with total hip replacements to particles of commercially pure titanium and chromium orthphosphate (a corrosion product from cobalt‐chromium alloy implants) were studied. In addition, these phagocytosable particles were added to cultured mononuclear cells isolated from the interfacial membrane of 14 patients with failed implants. Peripheral blood monocytes from patients who had had a total hip replacement produced significantly higher levels of interleukin‐1 (both interleukin‐1α and interleukin‐1β) and prostaglandin E 2 follwing particulate stimulation than those from normal volunteers. Supernatants from both titanium and chromium orthophosphate‐stimulated peripheral blood monocytes from the volunteers and patients with total hip replacement induced bone resorption (assayed in organ cultures of newborn mouse calvariae)and the proliferation of human fibroblasts. The levels of bone resorption were significantly higher (p < 0.05) in patients with implants that in normal volunteers. There were no significant differences in the responses of cells between patients with focal osteolysis and those without osteolysis. Interfacial membrane mononuclear cells also produced high levels of interleukin‐1α, interleukin‐1β, and prostaglandin E 2 and expressed bone resorptive activities following stimulation with either titanium or chromium orthophosphate. More importantly, interfacial membrane mononuclear cells “spontaneously” produced high levels of prostaglandin E 2 that were comparable with the response of peripheral blood monocytes stimulated with particulate wear debris. The clinical relevance of this study is 2‐fold. First, mononuclear cells from patients with total hip replacement were some‐how “sensitized” to metal particles in comparison with mononuclear cells from individuals without an implant. Second, the chromium orthophosphate corrosion product was a potent macrophage/monocyte activator and may contribute to macrophage‐mediated osteolysis and aseptic loosening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100150107

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 201

Metadata

Authors
Lee, S., Brennan, F. R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., & Glant, T. T.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1997-01
Volume
15
Issue
1
Pages
40-49
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W1970700880
Cited by
201
References
1
FWCI
10.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human monocyte/macrophage response to cobalt‐chromium corrosion products and titanium particles in patients with total joint replacements. https://app.cochat.ai/papers/10.1002/jor.1100150107
The paper
Lee, S., Brennan, F. R., Jacobs, J. J., Urban, R. M., Ragasa, D. R., & Glant, T. T. (1997). Human monocyte/macrophage response to cobalt‐chromium corrosion products and titanium particles in patients with total joint replacements. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100150107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.