Cited by 387Orthopaedic implants and arthroplastyOrthopedic Infections and TreatmentsTitanium Alloys Microstructure and Properties

Composition and morphology of wear debris in failed uncemented total hip replacement

Shanbhag, AS, Jacobs, JJ, Glant, TT, Gilbert, JL, Black, J, Galante, JO·1994·The Journal of Bone and Joint Surgery. British volume

Abstract

Interfacial membranes collected at revision from 11 failed uncemented Ti-alloy total hip replacements were examined. Particles in the membranes were characterised by electron microscopy, microchemical spectroscopy and particle size analysis. Most were polyethylene and had a mean size of 0.53 micron +/- 0.3. They were similar to the particles seen in the base resin used in the manufacture of the acetabular implants. Relatively few titanium particles were seen. Fragments of bone, stainless steel and silicate were found in small amounts. Most of the polyethylene particles were too small to be seen by light microscopy. Electron microscopy and spectroscopic techniques are required to provide an accurate description of this debris.

Integrity signals

Registry

Crossref · 10.1302/0301-620x.76b1.8300684

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wear byproducts from total joint replacements include particulate polymeric, ceramic, and metallic debris and metallic ions, which cause pro-inflammatory responses that can persist for the life of the implant.

    “The byproducts of wear include particulate polymeric, ceramic and metallic debris (mostly in the nano, submicron, and micron size range) and in the case of metal-on-metal implants, metallic ions [143]. These byproducts are well known to cause pro-inflammatory responses which can persist for the life of the implant [144,145].”

Cited by

Sorted by citations

Authors
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J.
Affiliations
Rush University (US)
Venue
The Journal of Bone and Joint Surgery. British volume
Published
1994-01
Volume
76-B
Issue
1
Pages
60-67
ISSN
  • 0301-620X (ISSN-L)
  • 2044-5377
OpenAlex
W1914858881
Cited by
387
References
0
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 5 · 2016: 5 · 2015: 4 · 2014: 12 · 2013: 11 · 2012: 9
FWCI
26.08
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Bone and Joint Surgery - British Volume (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
  • Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
Keywords
wear debris, cementless total hip arthroplasty, revision hip arthroplasty, polyethylene wear particles, titanium alloys, interfacial membrane, particle size, implant failure, bone fragments, stainless steel particles, silicate particles
MeSH terms
Aged, Cementation, Female, Hip Joint, Hip Prosthesis, Humans, Male, Microscopy, Electron, Scanning, Middle Aged, Particle Size, Polyethylenes, Prosthesis Failure, Reoperation, Titanium, Spectroscopy, Fourier Transform Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review