The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Relationships between bone morphology and bone elastic properties can be accurately quantified using high‐resolution computer reconstructions
Abstract
It would be advantageous if the mechanical properties of trabecular bone could be directly inferred from stereomorphometric parameters. For that purpose, apparent density and mean intercept length, as measures of bone mass and directionality (fabric), are commonly correlated with the elastic characteristics of bone samples, as determined in compression tests. However, complete and accurate relationships have not yet been established in this way. This may be due not only to the occurrence of artifacts in both the stereomorphometric and the mechanical assessments but also to an inherent inadequacy of mean intercept length in characterizing the full mechanical significance of bone architecture or nonhomogeneities in trabecular tissue properties not accounted for in stereomorphometry. In this study, we introduce a computer modeling approach allowing these biases to be eliminated. With use of high‐resolution three‐dimensional computer reconstructions of trabecular bone specimens for stereomorphometry and for microstructural finite element models to simulate mechanical tests, unbiased comparisons become feasible. The purpose was to investigate if accurate and complete relationships can be established in this way. Four different fabric measures were considered: mean intercept length and three volume‐based ones. Compliance matrices were calculated from fabric tensors, with use of the mathematical relationship proposed by Cowin for 29 vertebral whale‐bone specimens. These were correlated with the compliance constants determined directly from the microstructural finite element, model simulation. The nine orthotropic elastic constants of all 29 specimens were well predicted from their stereomorphometric fabric and volume fraction values, with correlation coefficients ranging from R = 0.9934 to O. 9963. When individual compliance components were considered (1/E i,. 1/G ij, or ‐v ij/E i), correlation coefficients ranged from R = 0.924 to 0.9X2. All four fabric measures performed equally well. It is concluded that volume fraction and fabric measures correlate highly with the apparent elastic properties of bone samples, provided the anisotropy and nonhomgoencity in the elastic properties of the trabecular tissue itself have negligible effects on the apparent propertie Whether this is true for bone in general remains to be seen, as only a subset was analyzed here. These methods, however, can be valuable in similar assessments of other subsets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Self-citationThe relationship between the elasticity tensor and the fabric tensor
Cowin, S. C. (1985) · Mechanics of Materials · doi:10.1016/0167-6636(85)90012-2 · Cited by 570
Cited by
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Bone fragility in diabetes: novel concepts and clinical implications
Hofbauer, L. C., Busse, B., Eastell, R., Ferrari, S., Frost, M., Müller, R., Burden, A. M., Rivadeneira, F., Napoli, N., & Rauner, M. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00347-8 · Cited by 440
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207
Metadata
- Authors
- Van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1998-01
- Volume
- 16
- Issue
- 1
- Pages
- 23-28
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2076266647
- Cited by
- 184
- References
- 3
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationships between bone morphology and bone elastic properties can be accurately quantified using high‐resolution computer reconstructions. https://app.cochat.ai/papers/10.1002/jor.1100160105
- The paper
- Van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1998). Relationships between bone morphology and bone elastic properties can be accurately quantified using high‐resolution computer reconstructions. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100160105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.