The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Local tissue properties in bone healing: Influence of size and stability of the osteotomy gap
Abstract
To characterize the site‐specific mechanical and histological properties in fracture repair and to relate these properties to the initial mechanical situation, an experimental fracture model was used in the metatarsus of 42 sheep. the mechanical situation of a transverse osteotomy was described by three gap sizes (1,2, or 6 mm) and two amounts of strain (7 or 31 %). An external fixator that allowed a defined axial movement provided control of these settings. Nine weeks following surgery, the healing area was dissected and tensile and compressive properties were measured in subregions of the fracture gap and the periosteal callus. The central, sagittal section was used for quantitative histology. We found the quality of the tissue along the osteotomy line to be most important for regaining mechanical stability. Increasing the size of osteotomy gaps resulted in poorer mechanical and histological qualities, and the repair process was less complete. Interfragmentary strain did not significantly influence the repair process. The smaller strain levels had already stimulated the secondary repair process, and this stimulatory effect could not be further enhanced by increasing the amount of strain. Our finding that large gaps between bone segments were not as well healed as were smaller gaps suggests that it is advantageous to avoid large gaps in fracture treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled mechanical stimulation in the treatment of tibial fractures
KENWRIGHT, J., & GOODSHIP, A. E. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198904000-00006 · Cited by 373
Cited by
Fracture healing: The diamond concept
Giannoudis, P. V., Einhorn, T. A., & Marsh, D. (2007) · Injury · doi:10.1016/s0020-1383(08)70003-2 · Cited by 1,092
Lacroix, D., & Prendergast, P. J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00086-6 · Cited by 681
Bone fracture healing: Cell therapy in delayed unions and nonunions
Gómez-Barrena, E., Rosset, P., Lozano, D., Stanovici, J., Ermthaller, C., & Gerbhard, F. (2015) · Bone · doi:10.1016/j.bone.2014.07.033 · Cited by 421
Shear movement at the fracture site delays healing in a diaphyseal fracture model
Augat, P., Burger, J., Schorlemmer, S., Henke, T., Peraus, M., & Claes, L. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00098-6 · Cited by 369
Self-citationFundamentals of Biomechanics in Tissue Engineering of Bone
Athanasiou, K. A., Zhu, C.-F., Lanctot, D. R., Agrawal, C. M., & Wang, X. (2000) · Tissue Engineering · doi:10.1089/107632700418083 · Cited by 301
Metadata
- Authors
- Augat, P., Margevicius, K., Simon, J., Wolf, S., Suger, G., & Claes, L.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1998-07
- Volume
- 16
- Issue
- 4
- Pages
- 475-481
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1982941239
- Cited by
- 204
- References
- 1
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.