Sequential labelling of microdamage in bone using chelating agents
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Basic fuchsin labels microcracks, but a series of stains is required to differentiate between preexisting and test‐induced microcracks and to label their growth in vitro. Basic fuchsin and five chelating agents—alizarin complexone, calcein, calcein blue, oxytetracycline, and xylenol orange—were randomly assigned to label microcracks in sequential rib sections from 10 donors. The density, length, and location of the microcracks did not differ significantly between he six stains, suggesting that each was equally effective in detecting microcracks. Paired specimens of trabecular bone were machined from bovine tibiae, stained with oxytetracycline, and fatigued in compression. One specimen from each pair was then stained with xylenol orange. Preexisting microdamage was stained with oxytetracycline, propagating microcracks with both stains and new, test‐initiated damage with xylenol orange. Chelating agents are site‐specific markers of the initiation and growth of microcracks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“(25, 26) have enabled more in-depth study of the relationships among microcracking, microstructure, and macroscale mechanical properties.”
Microfractures and microcracks in subchondral bone: are they relevant to osteoarthrosis?
Burr, D. B., & Radin, E. L. (2003) · Rheumatic Disease Clinics of North America · doi:10.1016/s0889-857x(03)00061-9 · Cited by 316
Trabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220
“Alternatively, a sequential fluorescent labeling technique has been utilized to differentiate preexisting damage from damage sustained by in vitro mechanical testing (Lee et al., 2000; O’Brien et al., 2002).”
MethodDamage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59
Fatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47
Self-citation
Metadata
- Authors
- Lee, T. C., Arthur, T. L., Gibson, L. J., & Hayes, W. C.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2000-03
- Volume
- 18
- Issue
- 2
- Pages
- 322-325
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2001613114
- Cited by
- 101
- References
- 1
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.