The DOI matches its Crossref record; 173 of the 174 references it cites were found in a registry or an index; 47 of the 225 sources its claims cite were checked for support.
Bone Mechanical Properties in Healthy and Diseased States
Open accessAbstract
Review of bone mechanics across length scales, including cortical bone, trabecular bone, and whole bones, covering elasticity, yield, fracture, fatigue, and damage.
Overview
CoChat Summary
TL;DR
This review synthesizes current knowledge of bone mechanical behavior from the nanoscale to whole-bone scale in healthy, aging, and diseased states. It emphasizes porosity/bone quantity and bone-quality parameters such as cross-linking and protein composition as determinants of cortical, trabecular, and whole-bone stiffness, strength, toughness, fatigue, and damage.
Key findings
- Cortical bone has 5–15% porosity and trabecular bone 40–95%; cortical bone is anisotropic, strongest in longitudinal compression and weakest in transverse tension, with mode I fracture toughness \(K_{IC}\) of 2–6 MPa√m, lower for longitudinal than transverse fracture and lower at high strain rates.
- With aging, cortical tensile/compressive strength declines ~2% per decade from the third decade, tensile ultimate strain declines ~10% per decade from 5% at age 20–30 to <1% above age 80, and fracture toughness declines ~4% per decade; trabecular modulus and strength decline ~10% per decade, and proximal femoral strength declines ~10–12% per decade (~50% from early to late adulthood).
- Human trabecular bone apparent modulus ranges from 10 to 3,000 MPa and strength from 0.1 to 30 MPa; 70–90% of the variance in modulus and strength is explained by volume fraction or apparent density, with power-law exponents of ~2–3 for modulus and ~2 for compressive strength.
- Bone quality matters: nonenzymatic glycation cross-links are associated with increased brittleness, diabetes is associated with lower bone toughness and possibly heightened AGE accumulation, and long-term antiresorptive therapy is associated with decreased toughness.
Methods
- Narrative review of bone mechanics across length scales from hundreds of nanometers to tens of centimeters, covering cortical bone, trabecular bone, whole bones, and material behaviors including elasticity, yield, fracture, fatigue, and damage.
- No primary data collection or systematic search/meta-analysis is described; the review synthesizes in vitro, in vivo, imaging, analytical, and finite element modeling literature.
- It discusses bone quantity (density, porosity) and bone quality (cross-linking, protein composition) and identifies future research avenues.
Limitations
- Stated in the paper: no consensus exists on the most accurate multiaxial yield criterion for trabecular bone, largely because none has been validated with an independent set of specimens; few data are available on whether aging or disease affect trabecular tissue differently than cortical tissue; the mechanistic link between microdamage and increased fracture risk has not been established; and consensus has yet to emerge on Raman spectroscopy readouts as indicators of bone fragility.
- Evident from the text: as a narrative review, it does not report a systematic search strategy, inclusion criteria, or quantitative synthesis, and its conclusions draw on heterogeneous ex vivo, animal, and modeling studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
43 Valid · 4 Not valid · 117 Not checked · 68 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [9] source
- Supportedcites [10] source
The Introduction states that microdamage has been directly associated with modulus degradation. The Results compare measured and predicted elastic-modulus degradation in cyclically damaged cortical bone, and the Conclusions say the relationship agrees with experimental observations. Page numbers are not supplied in our copy. (LLM, conf=0.94)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Preliminary values of fracture toughness at the microscale appear to be similar to those measured at the macroscale (41).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [41] source
The Results & discussion section (“Fracture characteristics”) reports microscale scratch-test toughness values of 3.15 ± 0.56 and 3.49 ± 0.80 MPa√m. It explicitly says these fall within the 2.2–4.6 MPa√m range reported for macroscopic fracture tests. (LLM, conf=0.94)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [75] Rubin MR, 2016, PLOS ONE source
The Abstract reports increased skeletal AGEs and lower bone toughness in a type 1 diabetic mouse model, with higher AGEs correlating with lower macroscopic toughness. The Discussion likewise says AGE accumulation co-exists with bone deterioration, supporting the claim’s tentative wording. (LLM, conf=0.91)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [48] source
The Conclusion states that long-term antiresorptive treatment can affect bone toughness through reductions in intrinsic and extrinsic toughening mechanisms. The Loss of Intrinsic Toughening section reports reduced fracture toughness in cortical bone from bisphosphonate-treated patients, supporting the citing sentence’s hedged concern. (LLM, conf=0.92)
- Supportedcites [72] source
The mechanical-properties discussion (page not provided) says bisphosphonate treatment consistently reduces bone toughness and that toughness declines with longer treatment. The paper discusses this as a concern, while noting that whether the change occurs in human bone remains to be determined. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [73] source
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [70] source
- Supportedcites [71] source
The Discussion and conclusions state that differences in cortical bone fatigue life depended on treatment class and drug: alendronate reduced fatigue life, PTH increased it, and raloxifene and zoledronate did not change it. This supports the cited claim that mechanical effects differ among osteoporosis therapies. (LLM, conf=0.93)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
165 more claims · 23 with their cited sources checked
Create a free account to see all 232 claims and to verify the 12 references still open.
- Probably not a substantial claim. 25
- It may state two separate claims as one. 41
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“When loaded in tension along the longitudinal direction, cortical bone exhibits a bilinear stress–strain response in which a distinct yield point separates a linearly elastic region and a region of linear hardening that ends abruptly at a fracture strain of less than 3% (Figure 1a).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“Tensile ultimate strain decreases by approximately 10% per decade, from a high of 5% strain at age 20–30 years to a low of less than 1% strain above age 80 years.”
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303 · cited 1×
“Measures of trabecular architecture include trabecular thickness, trabecular spacing, trabecular number, connectivity density, structure model index (SMI; a measure of how rod-like versus plate-like the architecture is), and the degree of anisotropy (83).”
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · cited 1×
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209 · cited 3×
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 1×
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
Self-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961 · cited 1×
“Using this approach, investigators attributed the experimentally observed dependence of Young’s modulus and compressive strength on apparent density raised to the second power to bendingdominated linear elastic behavior and failure by buckling (127).”
Riggs, B. L., Melton, L. J., Robb, R. A., Camp, J. J., Atkinson, E. J., Peterson, J. M., Rouleau, P. A., McCollough, C. H., Bouxsein, M. L., & Khosla, S. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040916 · Cited by 925 · cited 2×
“For the vertebrae, an increase in the cross-sectional area with aging has been reported for both men and women (154), and one study found that this increase was three times greater in men than in women (158).”
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924 · cited 1×
“Elastic moduli measured by nanoindentation are on the order of 23 GPa and 26 GPa for osteonal and interstitial lamellae, respectively, in the longitudinal direction (36, 37), and are approximately 45% lower in the transverse direction (37).”
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Research works printed but not linked: 2
- Frost HM, 1960, Henry Ford Hosp. Bull., 8, 27
- Dong XN, 2005, Mech. Chem. Biosyst., 2, 63
Cited by
Porous scaffolds for bone regeneration
Abbasi, N., Hamlet, S., Love, R. M., & Nguyen, N.-T. (2020) · Journal of Science: Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.01.007 · Cited by 858
“variations in compressive strength and tensile values in different regions of bone [80].”
BackgroundRecent Progress on Polymer Materials for Additive Manufacturing
Tan, L. J., Zhu, W., & Zhou, K. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003062 · Cited by 740
Applications of Magnesium and Its Alloys: A Review
Tan, J., & Ramakrishna, S. (2021) · Applied Sciences · doi:10.3390/app11156861 · Cited by 350
Natural and Synthetic Polymers for Bone Scaffolds Optimization
Donnaloja, F., Jacchetti, E., Soncini, M., & Raimondi, M. T. (2020) · Polymers · doi:10.3390/polym12040905 · Cited by 324
“Native bone tissue physical characteristics are summarized in Table 1 [3,4].”
BackgroundStrategies for Bone Regeneration: From Graft to Tissue Engineering
Battafarano, G., Rossi, M., De Martino, V., Marampon, F., Borro, L., Secinaro, A., & Del Fattore, A. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22031128 · Cited by 295
“(with a porosity ranging from 40% to 95% [4]) and less dense than cortical bone, giving this spongy bone a more flexible and weaker structure.”
Background
Metadata
- Authors
- Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I.
- Affiliations
- Boston University (US)
- Corresponding author
- Morgan, Elise F.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2018-06-04
- Volume
- 20
- Issue
- 1
- Pages
- 119-143
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- PMC
- PMC6053074
- OpenAlex
- W2807165335
- Cited by
- 1,026
- References
- 174
- Citations by year
- 2026: 163 · 2025: 223 · 2024: 194 · 2023: 150 · 2022: 136 · 2021: 114 · 2020: 37 · 2019: 8 · 2018: 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OpenBU (Boston University) (submittedVersion, cc-by)
- Funders
- National Science Foundation (1266243)
- National Institutes of Health (AR054620)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R56AR054620, R01AR054620)
- Division of Civil, Mechanical and Manufacturing Innovation
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- bone mechanical properties, bone mechanics, osteoporosis, diabetes mellitus, cortical bone, trabecular bone, elasticity, yield, fracture, fatigue (material), damages, bone mineral density, porosity, crosslinking, aging
- MeSH terms
- Aging, Bone and Bones, Bone Diseases, Diabetes Mellitus, Elasticity, Humans, Models, Theoretical, Osteoporosis, Quality of Life, Stress, Mechanical, Viscosity, Bone Density, Porosity, Anisotropy, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bone Mechanical Properties in Healthy and Diseased States. https://app.cochat.ai/papers/10.1146/annurev-bioeng-062117-121139
- The paper
- Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018). Bone Mechanical Properties in Healthy and Diseased States. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-062117-121139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.