Viscoelastic properties of chondrocytes from normal and osteoarthritic human cartilage
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The deformation behavior and mechanical properties of articular chondrocytes are believed to play an important role in their response to mechanical loading of the extracellular matrix. This study utilized the micropipette aspiration test to measure the viscoelastic properties of chondrocytes isolated from macroscopically normal or end‐stage osteoarthritic cartilage. A three‐parameter standard linear solid was used to model the viscoelastic behavior of the cells. Significant differences were found between the mechanical properties of chondrocytes isolated from normal and osteoarthritic cartilage. Specifically, osteoarthritic chondrocytes exhibited a significantly higher equilibrium modulus (0.33 ± 0.23 compared with 0.24 ± 0.11 kPa), instantaneous modulus (0.63 ± 0.51 compared with 0.41 ± 0.17 kPa), and apparent viscosity (5.8 ± 6.5 compared with 3.0 ± 1.8 kPa‐s) compared with chondrocytes isolated from macroscopically normal, nonosteoarthritic cartilage. The elastic moduli and relaxation time constant determined experimentally in this study were used to estimate the apparent biphasic properties of the chondrocyte on the basis of the equation for the gel relaxation time of a biphasic material. The differences in viscoelastic properties may reflect alterations in the structure and composition of the chondrocyte cytoskeleton that have previously been associated with osteoarthritic cartilage. Coupled with earlier theoretical models of cell‐matrix interactions in articular cartilage, the increased elastic and viscous properties suggest that the mechanical environment of the chondrocyte may be altered in osteoarthritic cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423
Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration
Evans, E., & Yeung, A. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82660-8 · Cited by 788
Armstrong, C. G., & Mow, V. C. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264010-00013 · Cited by 770
Chondrocyte deformation and local tissue strain in articular cartilage: A confocal microscopy study
Guilak, F., Ratcliffe, A., & Mow, V. C. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130315 · Cited by 475
Self-citationGuilak, F., & Mow, V. C. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00105-6 · Cited by 471
Self-citationPassive mechanical properties of human leukocytes
Schmid-Schönbein, G. W., Sung, K. L., Tözeren, H., Skalak, R., & Chien, S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84726-1 · Cited by 417
Thoumine, O., & Ott, A. (1997) · Journal of Cell Science · doi:10.1242/jcs.110.17.2109 · Cited by 410
Theret, D. P., Levesque, M. J., Sato, M., Nerem, R. M., & Wheeler, L. T. (1988) · Journal of Biomechanical Engineering · doi:10.1115/1.3108430 · Cited by 382
Sato, M., Theret, D. P., Wheeler, L. T., Ohshima, N., & Nerem, R. M. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891183 · Cited by 373
Cited by
Mechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Biomechanics approaches to studying human diseases
Lee, G. Y. H., & Lim, C. T. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.01.005 · Cited by 485
Self-citationGuilak, F., & Mow, V. C. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00105-6 · Cited by 471
Self-citationHuman cardiac organoids for the modelling of myocardial infarction and drug cardiotoxicity
Richards, D. J., Li, Y., Kerr, C. M., Yao, J., Beeson, G. C., Coyle, R. C., Chen, X., Jia, J., Damon, B., Wilson, R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0539-4 · Cited by 439
Kreuz, P. C., Erggelet, C., Steinwachs, M. R., Krause, S. J., Lahm, A., Niemeyer, P., Ghanem, N., Uhl, M., & Südkamp, N. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.06.020 · Cited by 381
GUILAK, F., ALEXOPOULOS, L. G., UPTON, M. L., YOUN, I., CHOI, J. B., CAO, L., SETTON, L. A., & HAIDER, M. A. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1346.011 · Cited by 357
Self-citationDarling, E. M., Topel, M., Zauscher, S., Vail, T. P., & Guilak, F. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.019 · Cited by 349
Self-citationViscoelastic properties of zonal articular chondrocytes measured by atomic force microscopy
Darling, E. M., Zauscher, S., & Guilak, F. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.12.003 · Cited by 329
Self-citationDarling, E. M., Zauscher, S., Block, J. A., & Guilak, F. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.083097 · Cited by 311
Self-citationRocio Servin-Vences, M., Moroni, M., Lewin, G. R., & Poole, K. (2017) · eLife · doi:10.7554/elife.21074 · Cited by 271
Schillers, H., Rianna, C., Schäpe, J., Luque, T., Doschke, H., Wälte, M., Uriarte, J. J., Campillo, N., Michanetzis, G. P. A., Bobrowska, J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05383-0 · Cited by 268
The Effects of Osmotic Stress on the Viscoelastic and Physical Properties of Articular Chondrocytes
Guilak, F., Erickson, G. R., & Ting-Beall, H. P. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75434-9 · Cited by 250
“…interactions (Gu et al., 1997; Guilak and Mow, 2000; Mow et al., 1999) as well as for micropipette analysis of single cells (Jones et al., 1999; Trickey et al., 2000b) that the chondrocyte membrane does not structurally contribute to the mechanical properties of the cell at small strains.”
BackgroundMethodSelf-citationCarl, P., & Schillers, H. (2008) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-008-0524-3 · Cited by 231
“An increase of cell elasticity was shown for endothelial cells under high sodium conditions [48] and hyperaldosteronism [24, 45], for chondrocytes in arthritis [ 62 ], for airway smooth muscle cells in bronchial asthma [2], for erythrocytes in malaria [59], for cardiac muscle in ischemia [19], and several other condit…”
BackgroundAlexopoulos, L. G., Haider, M. A., Vail, T. P., & Guilak, F. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1579047 · Cited by 221
Self-citationReview on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“…0.37 MN [79] Chondrocyte Bovine articular 0.69–8 0.26 MN/C [106] [287] Bovine cartilage 2.55–2.7 C [276] [288] Human cartilage 0.36–0.67 0.4 MP [64] [85] Human femoral 1.1–1.3 0.36–0.38 AFM/MP [62] [82] Porcine cartilage 0.6–1.2 AFM [86] Endothelial Bovine aortic 0.32 MP [87] Bovine aortic…”
BackgroundMethodInfluentialThe role of the cytoskeleton in the viscoelastic properties of human articular chondrocytes
Trickey, W. R., Vail, T. P., & Guilak, F. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)0150-5 · Cited by 191
“In previous studies, we have shown that the mechanical behavior of the chondrocyte is that of a viscoelastic solid [26,48], and it has been assumed that the chondrocyte cytoskeleton is responsible for this ‘‘solid-like’’ elastic response due to its distribution and structure within the cell [10].”
BackgroundMethodResultInfluentialSelf-citation3D Printing and Electrospinning of Composite Hydrogels for Cartilage and Bone Tissue Engineering
De Mori, A., Peña Fernández, M., Blunn, G., Tozzi, G., & Roldo, M. (2018) · Polymers · doi:10.3390/polym10030285 · Cited by 206
“Bone is a hard and rigid tissue, whereas cartilage is soft, viscoelastic and flexible and these two tissues are different in several aspects [9].”
BackgroundChoi, J. B., Youn, I., Cao, L., Leddy, H. A., Gilchrist, C. L., Setton, L. A., & Guilak, F. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.01.009 · Cited by 194
“…et al., 2005b; Guilak and Mow, 2000) in combination with direct measurements of the mechanical properties of the cell (Trickey et al., 2006; Trickey et al., 2000; Trickey et al., 2004)and PCM (Alexopoulos et al., 2003; Alexopoulos et al., 2005c; Allen and Mao, 2004; Guilak et al., 2005).”
BackgroundSelf-citation
Metadata
- Authors
- Trickey, W. R., Lee, G. M., & Guilak, F.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 18
- Issue
- 6
- Pages
- 891-898
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2080636405
- Cited by
- 256
- References
- 22
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.