The DOI matches its Crossref record.
Correlation between the knee adduction torque and medial contact force for a variety of gait patterns
Open accessAbstract
The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. This study uses in vivo data collected from a single subject with an instrumented knee implant to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe‐out) with simultaneous collection of instrumented implant, video motion, and ground reaction data. For each trial, the knee adduction torque was measured externally while the total axial force applied to the tibial insert was measured internally. Based on data collected from the same subject performing treadmill gait under fluoroscopic motion analysis, a regression equation was developed to calculate medial contact force from the implant load cell measurements. Correlation analyses were performed for the stance phase and entire gait cycle to quantify the relationship between the knee adduction torque and both the medial contact force and the medial to total contact force ratio. When the entire gait cycle was analyzed, R2 for medial contact force was 0.77 when all gait trials were analyzed together and between 0.69 and 0.93 when each gait trial was analyzed separately (p < 0.001 in all cases). For medial to total force ratio, R2 was 0.69 for all trials together and between 0.54 and 0.90 for each trial separately (p < 0.001 in all cases). When only the stance phase was analyzed, R2 values were slightly lower. These results support the hypothesis that the knee adduction torque is highly correlated with medial compartment contact force and medial to total force ratio during gait. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25: 789–797, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 38
- 10.1016/S1440-2440(04)80030-6 · doi:10.1016/s1440-2440(04)80030-6
- 10.1002/1529-0131(199807)41:7<1233::AID-ART14>3.0.CO;2-L · DOI · Paper page
- 10.2106/00004623-198567080-00007 · DOI · Paper page
- 10.1002/jor.1100090114 · DOI · Paper page
- 10.1177/036354659202000612 · DOI · Paper page
- 10.1016/S0021-9290(98)00028-1 · DOI
- 10.1016/j.jbiomech.2004.02.011 · DOI · Paper page
- 10.1016/j.arth.2005.07.011 · DOI · Paper page
- 10.1016/S0736-0266(01)00081-X · doi:10.1016/s0736-0266(01)00081-x
- 10.1002/art.20132 · doi:10.1002/art.20132
- 10.2106/00004623-199072060-00017 · doi:10.2106/00004623-199072060-00017
- 10.1016/S0021-9290(97)00001-8 · DOI · Paper page
- 10.1016/0021-9290(94)90197-X · DOI · Paper page
- 10.1177/03635465030310032101 · DOI · Paper page
- 10.1007/978-3-642-50995-7_7 · doi:10.1007/978-3-642-50995-7_7
- Kane TR, 1985, Dynamics: Theory and Applications
- 10.1016/j.jbiomech.2004.03.031 · DOI · Paper page
- 10.1016/0021-9290(95)00178-6 · DOI · Paper page
- 10.1016/0021-9290(93)90098-Y · DOI · Paper page
- 10.1016/j.medengphy.2004.07.004 · doi:10.1016/j.medengphy.2004.07.004
- 10.1016/0021-9290(91)90019-J · DOI · Paper page
- 10.1016/j.jbiomech.2004.02.013 · DOI · Paper page
- 10.1017/CBO9781139171731 · DOI · Paper page
- CriptonPA.1993.Compressive characterization of ultra‐high molecular weight polyethylene with applications to contact stress analysis of total knee replacements. Master of Science Thesis. Queen's University Kingston Ontario.
- 10.1016/S0021-9290(03)00176-3 · doi:10.1016/s0021-9290(03)00176-3
- Bei Y, 2004, The relationship between contact pressure, insert thickness, and mild wear in total knee replacements, Comput Model Eng Sci, 6, 145
- 10.1123/jab.22.2.120 · doi:10.1123/jab.22.2.120
- Bryan JM, 1997, Proceedings of the 43rd Annual Meeting of the Orthopaedic Research Society, 718
- 10.1002/art.10923 · DOI
- Fransen M, 2001, Physical therapy is effective for patients with osteoarthritis of the knee: a randomized controlled clinical trial, J Rheumatol, 28, 156
- 10.1097/01.bor.0000171214.49876.38 · DOI
- MündermannA DyrbyCO AndriacchiTP.2005.Hip abductor strength may be critical for successful gait compensation in patients with medial compartment knee OA.In Proceedings of the 20th Congress of the International Society of Biomechanics August 2005 Cleveland. OH.
- 10.1016/S0030-5898(20)31924-6 · DOI · Paper page
- Guo M, The influence of foot progression angle on the knee adduction moment during walking and stair climbing in pain free individuals with knee osteoarthritis, Gait & Posture
- Fregly BJ, Design of patient‐specific gait modifications for knee osteoarthritis rehabilitation, IEEE Trans Biomed Eng
- 10.1115/1.1392310 · DOI · Paper page
- 10.1016/S0021-9290(97)00089-4 · DOI · Paper page
- FreglyBJ ReinboltJA KohBI et al.2006.Evaluation of a patient‐specific cost function to predict the influence of foot path on the knee adduction torque during gait.In Proceedings of the 7th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering 2006 March 22‐25 Juan‐les‐Pins France.
Cited by
Forefoot Strikers Exhibit Lower Running-Induced Knee Loading than Rearfoot Strikers
KULMALA, J.-P., AVELA, J., PASANEN, K., & PARKKARI, J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829efcf7 · Cited by 306
Chang, A. H., Moisio, K. C., Chmiel, J. S., Eckstein, F., Guermazi, A., Prasad, P. V., Zhang, Y., Almagor, O., Belisle, L., Hayes, K., et al. (2015) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2015.02.005 · Cited by 274
Werling, K., Bianco, N. A., Raitor, M., Stingel, J., Hicks, J. L., Collins, S. H., Delp, S. L., & Liu, C. K. (2023) · PLOS ONE · doi:10.1371/journal.pone.0295152 · Cited by 65
Hatfield, G. L., Costello, K. E., Astephen Wilson, J. L., Stanish, W. D., & Hubley-Kozey, C. L. (2021) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2021.03.038 · Cited by 15
Metadata
- Authors
- Zhao, D., Banks, S. A., Mitchell, K. H., D'Lima, D. D., Colwell, C. W., & Fregly, B. J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2007-03-07
- Volume
- 25
- Issue
- 6
- Pages
- 789-797
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2157126061
- Cited by
- 520
- References
- 0
- FWCI
- 16.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between the knee adduction torque and medial contact force for a variety of gait patterns. https://app.cochat.ai/papers/10.1002/jor.20379
- The paper
- Zhao, D., Banks, S. A., Mitchell, K. H., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2007). Correlation between the knee adduction torque and medial contact force for a variety of gait patterns. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.20379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.