Fracture healing in mice under controlled rigid and flexible conditions using an adjustable external fixator
The DOI matches its Crossref record.
Abstract
Mice are increasingly used to investigate mechanobiology in fracture healing. The need exists for standardized models allowing for adjustment of the mechanical conditions in the fracture gap. We introduced such a model using rigid and flexible external fixators with considerably different stiffness (axial stiffnesses of 18.1 and 0.82 N/mm, respectively). Both fixators were used to stabilize a 0.5 mm osteotomy gap in the femur of C57BL/6 mice (each n = 8). Three‐point bending tests, µCT, and histomorphometry demonstrated a different healing pattern after 21 days. Both fixations induced callus formation with a mixture of intramembranous and enchondral ossification. Under flexible conditions, the bending stiffness of the callus was significantly reduced, and a larger but qualitatively inferior callus with a significantly lower fraction of bone but a higher fraction of cartilage and soft tissue was formed. Monitoring of the animal movement and the ground reaction forces demonstrated physiological loading with no significant differences between the groups, suggesting that the differences in healing were not based on a different loading behavior. In summary, flexible external fracture fixation of the mouse femur led to delayed fracture healing in comparison to a more rigid situation. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1456–1462, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fracture healing under healthy and inflammatory conditions
Claes, L., Recknagel, S., & Ignatius, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.1 · Cited by 1,326
Self-citationFracture healing in osteoporotic bone
Cheung, W. H., Miclau, T., Chow, S. K.-H., Yang, F. F., & Alt, V. (2016) · Injury · doi:10.1016/s0020-1383(16)47004-x · Cited by 208
“[84] Rontgen V, Blakytny R, Matthys R, Landauer M, Wehner T, Gockelmann M, et al.”
BackgroundThe crucial role of neutrophil granulocytes in bone fracture healing
Institute of Orthopaedic Research and Biomechanics, U. O. U., Kovtun, A., Bergdolt, S., Wiegner, R., Radermacher, P., Huber-Lang, M., & Ignatius, A. (2016) · European Cells and Materials · doi:10.22203/ecm.v032a10 · Cited by 198
Self-citationSmall animal bone healing models: Standards, tips, and pitfalls results of a consensus meeting
Histing, T., Garcia, P., Holstein, J. H., Klein, M., Matthys, R., Nuetzi, R., Steck, R., Laschke, M. W., Wehner, T., Bindl, R., et al. (2011) · Bone · doi:10.1016/j.bone.2011.07.007 · Cited by 193
“endochondral versus intramembranous healing [55,58–60].”
BackgroundMethodInfluentialSelf-citationDistinct Effects of IL-6 Classic and Trans -Signaling in Bone Fracture Healing
Prystaz, K., Kaiser, K., Kovtun, A., Haffner-Luntzer, M., Fischer, V., Rapp, A. E., Liedert, A., Strauss, G., Waetzig, G. H., Rose-John, S., et al. (2018) · The American Journal of Pathology · doi:10.1016/j.ajpath.2017.10.011 · Cited by 142
Self-citationKroner, J., Kovtun, A., Kemmler, J., Messmann, J. J., Strauss, G., Seitz, S., Schinke, T., Amling, M., Kotrba, J., Froebel, J., et al. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3234 · Cited by 95
Self-citationThe inflammatory phase of fracture healing is influenced by oestrogen status in mice
Haffner-Luntzer, M., Fischer, V., Prystaz, K., Liedert, A., & Ignatius, A. (2017) · European Journal of Medical Research · doi:10.1186/s40001-017-0264-y · Cited by 60
“The surgery was conducted according to the published protocol [35].”
MethodSelf-citationWehrle, E., Wehner, T., Heilmann, A., Bindl, R., Claes, L., Jakob, F., Amling, M., & Ignatius, A. (2014) · Journal of Orthopaedic Research® · doi:10.1002/jor.22629 · Cited by 59
Self-citationMast Cells Trigger Disturbed Bone Healing in Osteoporotic Mice
Fischer, V., Ragipoglu, D., Diedrich, J., Steppe, L., Dudeck, A., Schütze, K., Kalbitz, M., Gebhard, F., Haffner-Luntzer, M., & Ignatius, A. (2020) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.4455 · Cited by 42
“To analyze the flexural rigidity of the fracture callus, a functional parameter for the healing outcome, a nondestructive threepoint-bending test of the fractured femurs was performed on day 21 after fracture as described previously.((33)) Briefly, after fixator removal, the bone was loaded with up to a maximum of 2 N…”
MethodSelf-citationMast Cells Drive Systemic Inflammation and Compromised Bone Repair After Trauma
Ragipoglu, D., Bülow, J., Hauff, K., Voss, M., Haffner-Luntzer, M., Dudeck, A., Ignatius, A., & Fischer, V. (2022) · Frontiers in Immunology · doi:10.3389/fimmu.2022.883707 · Cited by 34
“was performed as described previously (33).”
BackgroundMethodSelf-citationWnt1 boosts fracture healing by enhancing bone formation in the fracture callus
Haffner-Luntzer, M., Ragipoglu, D., Ahmad, M., Schoppa, A., Steppe, L., Fischer, V., Luther, J., Yorgan, T., Bockamp, E., Amling, M., et al. (2020) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.4797 · Cited by 24
“To analyze the mechanical competence of the bones, biomechanical testing of the intact and fractured femurs of mice euthanized at day 21 after fracture was performed using a nondestructive three-point-bending test as described.((27)) Briefly, after removal of the fixator, the bone was loaded with up to 2 N in a materi…”
MethodSelf-citation
Metadata
- Authors
- Röntgen, V., Blakytny, R., Matthys, R., Landauer, M., Wehner, T., Göckelmann, M., Jermendy, P., Amling, M., Schinke, T., Claes, L., & Ignatius, A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2010-04-22
- Volume
- 28
- Issue
- 11
- Pages
- 1456-1462
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2065384730
- Cited by
- 115
- References
- 0
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.