Using surface‐enhanced Raman scattering (SERS) and fluorescence spectroscopy for screening yeast extracts, a complex component of cell culture media
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Yeastolate or yeast extract, which are hydrolysates produced by autolysis of yeast, are often employed as a raw material in the media used for industrial mammalian cell culture. The source and quality of yeastolate can significantly affect cell growth and production; however, analysis of these complex biologically derived materials is not straightforward. The best current method, liquid chromatography–mass spectrometry (LC‐MS), is time‐consuming and requires extensive expertise. This study describes the use of surface‐enhanced Raman scattering (SERS) and fluorescence excitation–emission matrix (EEM) spectroscopy coupled with robust principal component analysis (ROBPCA) for the rapid and facile characterization and discrimination of yeast extracts in aqueous solution. SERS using silver colloids generates time‐dependent signals, where adenine is the strongest contributor, and the spectra are stable and reproducible (< ~3%) at 180 min after mixing. Combining this spectral behavior with chemometric methods enables SERS to be used in discriminating between different yeastolate sources, for assessing lot‐to‐lot variability, and, potentially, to monitor storage‐induced compositional changes. Fluorescence EEM combined with multiway ROBPCA also provides a rapid and inexpensive method for the discrimination of yeastolate, yielding results in terms of sample discrimination very similar to that obtained with SERS. However, the EEM data does not provide the same level of chemical information that is provided by the SERS. Thus, the combination of these two methodologies has the potential to be extremely useful in biopharmaceutical manufacturing, as well as for the rapid characterization and screening of biogenic hydrolysates from animal or plant sources. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“EEM is a very effective and useful tool for the qualitative characterization of nearly all the different solutions that are encountered in biopharmaceutical manufacturing: CCM [20,21,23,29], biogenic raw materials [22], bioprocess broths [30][31][32], and proteins [33].”
From Cell culture media analysis using rapid spectroscopic methods (2018) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,440
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
ROBPCA: A New Approach to Robust Principal Component Analysis
Hubert, M., Rousseeuw, P. J., & Vanden Branden, K. (2005) · Technometrics · doi:10.1198/004017004000000563 · Cited by 1,052
Barcoding bacterial cells: a SERS‐based methodology for pathogen identification
Patel, I. S., Premasiri, W. R., Moir, D. T., & Ziegler, L. D. (2008) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2064 · Cited by 207
Research works printed but not linked: 55
- Kelly M., 1983, Industrial Enzymology, the Application of Enzymes in Industry, 457
- 10.1023/A:1008811711205 · doi:10.1023/a:1008811711205
- Dahod S. K., 1999, Manual of Industrial Microbiology and Biotechnology, 213
- Chevalot I., 2010, ESACT Proceedings, 4, 843
- 10.1002/bit.1078 · DOI
- 10.1002/bit.10608 · DOI
- 10.1007/s00253-009-1903-1 · DOI
- 10.1007/BF00749653 · DOI
- 10.1002/bit.22528 · DOI · Paper page
- 10.1002/bit.22529 · DOI · Paper page
- 10.1016/S0167-7012(97)00032-8 · DOI
- 10.1002/btpr.131 · doi:10.1002/btpr.131
- 10.1021/bp980001j · DOI
- 10.1002/bit.22813 · DOI · Paper page
- Pelletier M. J., 1999, Analytical Applications of Raman Spectroscopy
- 10.1007/978-0-387-46312-4 · DOI · Paper page
- 10.1366/11-06383 · DOI · Paper page
- 10.1023/B:JOFL.0000014667.62333.eb · doi:10.1023/b:jofl.0000014667.62333.eb
- 10.1016/S0925-4005(98)00195-6 · DOI
- 10.1016/j.foodchem.2005.02.045 · DOI
- 10.1366/0003702991946695 · doi:10.1366/0003702991946695
- 10.1016/S0165-9936(02)01201-3 · doi:10.1016/s0165-9936(02)01201-3
- 10.1016/0304-4203(95)00062-3 · DOI · Paper page
- 10.1021/es0503074 · DOI
- 10.1016/j.aca.2006.08.034 · doi:10.1016/j.aca.2006.08.034
- 10.17221/687-CJFS · DOI · Paper page
- 10.1366/000370206776342643 · DOI
- 10.1002/jrs.2586 · DOI
- 10.1021/ac902337c · DOI · Paper page
- 10.1002/9780470035641 · DOI · Paper page
- 10.1021/ac0501238 · DOI · Paper page
- 10.1021/ja066263w · DOI · Paper page
- 10.1016/j.cbpa.2005.07.001 · DOI
- 10.1002/cphc.200390004 · DOI · Paper page
- 10.1366/000370209789806849 · DOI
- 10.1366/000370210791414326 · DOI
- 10.1366/10-06173 · DOI
- 10.1366/10-06184 · DOI
- 10.1002/jrs.1349 · DOI
- 10.1002/jrs.2475 · DOI
- 10.1021/j100214a025 · DOI · Paper page
- Martens H., 1989, Multivariate Calibration
- 10.1366/0003702824639114 · DOI
- 10.1021/ac00297a042 · DOI · Paper page
- 10.1021/ac60214a047 · DOI · Paper page
- 10.1016/j.chemolab.2004.09.009 · DOI
- 10.1002/cem.978 · DOI · Paper page
- Mathworks Inc. Cambridge MA 1994‐2008.
- 10.1088/0953-8984/14/18/202 · DOI · Paper page
- 10.1021/jp010789f · DOI · Paper page
- 10.1002/jrs.1443 · DOI
- 10.1039/c0an00612b · doi:10.1039/c0an00612b
- 10.1039/b203830g · doi:10.1039/b203830g
- 10.1039/b408775e · DOI
- 10.1002/jrs.2548 · doi:10.1002/jrs.2548
Cited by
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
“Conventional Raman spectroscopy is not suitable for the analysis of most types of yeastolate because of its very strong fluorescence.(35) The use of longer excitation wavelength (993, 1064 nm) light can reduce the effect, but the Raman signal tends to be weak and adversely affected by the considerable shot noise from…”
InfluentialSelf-citationZhang, Y., Zhao, S., Zheng, J., & He, L. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.02.006 · Cited by 158
Liu, J., & Huang, Q. (2016) · Applied Spectroscopy · doi:10.1177/0003702816645605 · Cited by 45
Cell culture media analysis using rapid spectroscopic methods
Ryder, A. G. (2018) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2018.08.008 · Cited by 30
Self-citation
Metadata
- Authors
- Li, B., Sirimuthu, N. M. S., Ray, B. H., & Ryder, A. G.
- Affiliations
- Nanoscale Biophotonics Laboratory, School of Chemistry National University of Ireland Galway Galway Ireland
- Venue
- Journal of Raman Spectroscopy
- Publisher
- Wiley
- Published
- 2011-12-22
- Volume
- 43
- Issue
- 8
- Pages
- 1074-1082
- ISSN
- 0377-0486
- 1097-4555
- Cited by
- 33
- References
- 4
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using surface‐enhanced Raman scattering (SERS) and fluorescence spectroscopy for screening yeast extracts, a complex component of cell culture media. https://app.cochat.ai/papers/10.1002/jrs.3141
- The paper
- Li, B., Sirimuthu, N. M. S., Ray, B. H., & Ryder, A. G. (2012). Using surface‐enhanced Raman scattering (SERS) and fluorescence spectroscopy for screening yeast extracts, a complex component of cell culture media. Journal of Raman Spectroscopy. https://doi.org/10.1002/jrs.3141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.