Graphical enhancements to summary receiver operating characteristic plots to facilitate the analysis and reporting of meta‐analysis of diagnostic test accuracy data
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Diagnostic test accuracy (DTA) systematic reviews are conducted to summarize evidence on the accuracy of a diagnostic test including a critical evaluation of the primary studies. Where appropriate, the evidence is meta‐analyzed to obtain pooled estimates of effectiveness.In this study, we reviewed and critiqued three DTA guidance documents with respect to the graphical presentation of DTA meta‐analysis results. All three documents recommended the use of two forms of graphical presentation: (a) forest plots displaying meta‐analysis results for sensitivity (ie, the true positive rate) and specificity (ie, true negative rate) separately, and (b) Summary Receiver Operating Characteristic (SROC) curve to provide a global summary of test performance. Two primary shortcomings were identified: (a) lack of incorporation of quality assessment results into the main analysis and; (b) ambiguity with which the contribution of individual studies is represented on SROC curves. In response, two alternative graphical approaches were developed: A quality assessment enhanced SROC plot which displays the results from individual studies in the meta‐analysis with multiple indicators of quality assessed using QUADAS‐2; and A percentage study weights enhanced SROC plot which accurately portrays the percentage contribution each study makes to the meta‐analysis. The proposed enhanced SROC curves facilitate the exploration of DTA data, leading to a deeper understanding of the primary studies included in a DTA meta‐analysis including identifying reasons for between study heterogeneity and why specific study results may be divergent. Both plots can easily be produced in the free online interactive application, MetaDTA (https://crsu.shinyapps.io/dta_ma/).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy
(2023) · doi:10.1002/9781119756194 · Cited by 757
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90 · cited 2×
“Figure 4A shows the SROC plot presented in the original meta-analysis.(13) The solid red line represents the SROC curve, the dashed green lines show the 95% confidence limits and the solid triangles indicate the summary estimates (the upper triangle relates to a fixed effect analysis and the lower relates to a random…”
BackgroundMethod
Cited by
McGenity, C., Clarke, E. L., Jennings, C., Matthews, G., Cartlidge, C., Freduah-Agyemang, H., Stocken, D. D., & Treanor, D. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01106-8 · Cited by 290
Khraisha, Q., Put, S., Kappenberg, J., Warraitch, A., & Hadfield, K. (2023) · arXiv · doi:10.48550/arxiv.2310.17526 · Cited by 268
Khraisha, Q., Put, S., Kappenberg, J., Warraitch, A., & Hadfield, K. (2024) · Research Synthesis Methods · doi:10.1002/jrsm.1715 · Cited by 269
“For performance, we calculated sensitivity, specificity and accuracy, which are the commonly used metrics (e.g., Frömke et al. 24 and Patel et al. 25 ).”
Toljan, K., Amin, M., & Ontaneda, D. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.106984 · Cited by 9
Metadata
- Authors
- Patel, A., Cooper, N., Freeman, S., & Sutton, A.
- Venue
- Research Synthesis Methods
- Publisher
- Wiley
- Published
- 2020-08-12
- Volume
- 12
- Issue
- 1
- Pages
- 34-44
- ISSN
- 1759-2879 (ISSN-L)
- 1759-2887
- OpenAlex
- W3044451687
- Cited by
- 180
- References
- 4
- FWCI
- 9.87
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphical enhancements to summary receiver operating characteristic plots to facilitate the analysis and reporting of meta‐analysis of diagnostic test accuracy data. https://app.cochat.ai/papers/10.1002/jrsm.1439
- The paper
- Patel, A., Cooper, N., Freeman, S., & Sutton, A. (2021). Graphical enhancements to summary receiver operating characteristic plots to facilitate the analysis and reporting of meta‐analysis of diagnostic test accuracy data. Research Synthesis Methods. https://doi.org/10.1002/jrsm.1439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.