Liquid‐phase microextraction of basic drugs – Selection of extraction mode based on computer calculated solubility data
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The extractability of 58 different basic drugs by 3‐phase liquid‐phase microextraction (LPME) was studied. Extraction recoveries were correlated to solubility data and log D data calculated with a commercial computer program. The basic drugs were extracted from 1.5 mL water samples (pH 13) through approximately 15 μL of dodecyl acetate immobilized within the pores of a porous polypropylene hollow fibre (organic phase), and into 15 μL of 10 mM HCl (acceptor solution) present inside the lumen of the hollow fibre. Compounds with a calculated solubility below 1 mg/mL at pH 2 were poorly recovered and remained principally in the organic phase. For these drugs, 2‐phase LPME may be used as an alternative technique, where the aqueous acceptor phase is replaced by an organic solvent. In the solubility range 1–5 mg/mL, most drugs were effectively extracted (recovery > 30%), whereas drugs belonging to the solubility range 5–150 mg/mL were all extracted with recoveries above 30% by 3‐phase LPME. The hydrophilic nature of most drugs with solubilities above 150 mg/mL prevented them from entering the organic phase, and only those with log D >1.8 were effectively recovered by 3‐phase LPME. For drugs with log D < 1.8 (and solubility > 150 mg/mL), carrier‐mediated LPME was found to be the preferred technique, where an ion‐pair reagent (octanoic acid) was added to the sample. In the case of carrier‐mediated LPME, the volume of sample was decreased to 100 μL to facilitate rapid extractions. Based on the present work, the extractability of new compounds may easily be predicted to speed up method development. Extractions were also accomplished from plasma samples, where interactions between proteins and the drugs may reduce the extraction recovery. However, dilution of the plasma samples with water and adjustment of pH into the alkaline region effectively suppressed drug‐protein interactions for most of the drugs studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Self-citationLee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Self-citationBreadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Critical review on recent developments in solventless techniques for extraction of analytes
Nerín, C., Salafranca, J., Aznar, M., & Batlle, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2437-6 · Cited by 284
Analytical Microextraction: Current Status and Future Trends
Pawliszyn, J., & Pedersen-Bjergaard, S. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.291 · Cited by 123
Self-citation
Metadata
- Authors
- Pedersen‐Bjergaard, S., Rasmussen, K. E., Brekke, A., Ho, T. S., & Grønhaug Halvorsen, T.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2005-07
- Volume
- 28
- Issue
- 11
- Pages
- 1195-1203
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2168290837
- Cited by
- 51
- References
- 1
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid‐phase microextraction of basic drugs – Selection of extraction mode based on computer calculated solubility data. https://app.cochat.ai/papers/10.1002/jssc.200401935
- The paper
- Pedersen‐Bjergaard, S., Rasmussen, K. E., Brekke, A., Ho, T. S., & Grønhaug Halvorsen, T. (2005). Liquid‐phase microextraction of basic drugs – Selection of extraction mode based on computer calculated solubility data. Journal of Separation Science. https://doi.org/10.1002/jssc.200401935
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.