Simultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods
Open accessAbstract
Studies on the determination of seven kinds of phthalates, i. e. diethyl phthalate, dipropyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di‐(2‐ethylhexyl) phthalate, and dioctyl phthalate, and four parabens, i. e. methylparaben, ethylparaben, propylparaben, and butylparaben, in 15 kinds of cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc., by HPLC with diode array detection and GC‐MS in electron impact ionization mode with selected‐ion monitoring have been carried out. Methods have been developed for both qualitative and quantitative detection of phthalates and parabens. Extraction, clean‐up, and analysis procedures have been optimized. HPLC and GC‐MS determinations were performed after sonication‐assisted extraction with methanol and clean‐up with C18 SPE. These techniques permit detection of phthalates at a level of 10.0–100.0 μg/kg and of parabens at a level of 20.0–200.0 μg/kg. Overall recoveries were 85–108% with RSD values of 4.2–8.8%. Only one of the 15 examined samples was free from phthalates and parabens. The remaining 14 samples were found to contain at least three or more of these phthalates and/or parabens. The predominant phthalates and parabens detected in the studied samples were methylparaben, propylparaben, diethyl phthalate, dibutyl phthalate, dicyclohexyl phthalate, and di‐(2‐ethylhexyl) phthalate. The residue level is at 1.22–5289 mg/kg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silva, M. J., Malek, N. A., Hodge, C. C., Reidy, J. A., Kato, K., Barr, D. B., Needham, L. L., & Brock, J. W. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00164-8 · Cited by 158
Cited by
Darbre, P. D., & Harvey, P. W. (2008) · Journal of Applied Toxicology · doi:10.1002/jat.1358 · Cited by 697
Giulivo, M., Lopez de Alda, M., Capri, E., & Barceló, D. (2016) · Environmental Research · doi:10.1016/j.envres.2016.07.011 · Cited by 573
Endocrine disrupting chemicals in indoor and outdoor air
Rudel, R. A., & Perovich, L. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.025 · Cited by 546
Endocrine Disruptors and Asthma-Associated Chemicals in Consumer Products
Dodson, R. E., Nishioka, M., Standley, L. J., Perovich, L. J., Brody, J. G., & Rudel, R. A. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104052 · Cited by 542
Mathieu-Denoncourt, J., Wallace, S. J., de Solla, S. R., & Langlois, V. S. (2015) · General and Comparative Endocrinology · doi:10.1016/j.ygcen.2014.11.003 · Cited by 307
Metadata
- Authors
- Shen, H., Jiang, H., Mao, H., Pan, G., Zhou, L., & Cao, Y.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 30
- Issue
- 1
- Pages
- 48-54
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2063299059
- Cited by
- 185
- References
- 1
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods. https://app.cochat.ai/papers/10.1002/jssc.200600215
- The paper
- Shen, H., Jiang, H., Mao, H., Pan, G., Zhou, L., & Cao, Y. (2007). Simultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods. Journal of Separation Science. https://doi.org/10.1002/jssc.200600215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.