Macroporous gels prepared at subzero temperatures as novel materials for chromatography of particulate‐containing fluids and cell culture applications

Plieva, Fatima M., Galaev, Igor Yu., Mattiasson, Bo·2007·Journal of Separation Science

Abstract

Macroporous gels (MGs) with a broad variety of morphologies are prepared using the cryotropic gelation technique, i. e. gelation at subzero temperatures. These highly elastic hydrophilic materials can be produced from practically any gel‐forming system with a broad range of porosity extending from elastic and porous gels with pore sizes up to 1.0 μm to elastic and sponge‐like gels with pore sizes up to 100 μm. The versatility of the cryogelation technique is demonstrated by use of different chemical reactions (hydrogen bond formation, chemical cross‐linking of polymers, free radical polymerization) mainly in an aqueous medium. Appropriate control over solvent crystallization (formation of solvent crystals) and rate of chemical reaction during the cryogelation allows the reproducible preparation of cryogels with tailored properties. Different approaches, such as chemical modification of reactive groups, grafting of the pore surface with an appropriate polymer, or direct copolymerization with functional monomers are used for control of the surface chemistry of MGs. Typically, MGs with pore sizes up to 1.0 μm are produced in the shape of beads and MGs with pore size up to 100 μm are prepared as monoliths, discs, and sheets. The difference in porous structure of MGs defines the main applications of these porous materials. Elastic beaded MGs are mostly used as carriers for cell and enzyme immobilization or for capture of low‐molecular weight targets from particulate‐containing fluids in expanded‐bed mode. However, the elastic and sponge‐like MG monoliths with interconnected pores measuring hundreds of μm have been successfully used as monolithic columns for chromatography of particulate‐containing fluids (crude cell homogenates, viruses, whole cells, wastewater effluents) and as three‐dimensional scaffolds for mammalian cell culture applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.200700127

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 205

Metadata

Authors
Plieva, F. M., Galaev, I. Y., & Mattiasson, B.
Venue
Journal of Separation Science
Publisher
Wiley
Published
2007-07
Volume
30
Issue
11
Pages
1657-1671
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2050120453
Cited by
205
References
1
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macroporous gels prepared at subzero temperatures as novel materials for chromatography of particulate‐containing fluids and cell culture applications. https://app.cochat.ai/papers/10.1002/jssc.200700127
The paper
Plieva, F. M., Galaev, I. Y., & Mattiasson, B. (2007). Macroporous gels prepared at subzero temperatures as novel materials for chromatography of particulate‐containing fluids and cell culture applications. Journal of Separation Science. https://doi.org/10.1002/jssc.200700127

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.