Coupling of ionic liquid‐based headspace single‐drop microextraction with GC for sensitive detection of phenols
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A headspace single‐drop microextraction (SDME) based on ionic liquid (IL) has been developed for the gas chromatographic determination of phenols. The volume of IL microdrop used was 1 μL. After extraction, the analytes were desorbed from the drop in the injection port and the involatile IL was withdrawn into the microsyringe. To facilitate the withdrawal of IL the upper diameter of the split inlet liner was enlarged to some extent. Some parameters were optimized for the determination of phenols. Under the selected conditions, i.e., desorption for 100 s at 210°C after extraction for 25 min at 50°C in solutions (pH 3) containing 0.36 g/mL sodium chloride, the LODs, RSDs, and the average enrichment factors of phenols were 0.1–0.4 ng/mL, 3.6–9.5% (n = 5), and 35–794, respectively. The proposed procedure was applied to the determination of phenols in lake water and wastewater samples, and the spiked recoveries were in the range of 81–111% at a spiked level of 0.4 μg/mL. This method is a promising alternative for the sensitive determination of phenolic compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peng, J.-F., Liu, J.-F., Hu, X.-L., & Jiang, G.-B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.006 · Cited by 276
Direct Coupling of Ionic Liquid Based Single-Drop Microextraction and GC/MS
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2008) · Analytical Chemistry · doi:10.1021/ac071555g · Cited by 144
Liu, J., Chi, Y., & Jiang, G. (2005) · Journal of Separation Science · doi:10.1002/jssc.200401805 · Cited by 84
Cited by
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Recent Applications of Ionic Liquids in Separation Technology
Han, D., & Row, K. H. (2010) · Molecules · doi:10.3390/molecules15042405 · Cited by 560
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Impact of ionic liquids in environment and humans: An overview
Frade, R. F., & Afonso, C. A. (2010) · Human & Experimental Toxicology · doi:10.1177/0960327110371259 · Cited by 254
Metadata
- Authors
- Zhao, F., Li, J., & Zeng, B.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2008-09
- Volume
- 31
- Issue
- 16-17
- Pages
- 3045-3049
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2031353483
- Cited by
- 66
- References
- 3
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.