Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC‐MS
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method based on pressurized liquid extraction and LC‐MS/MS has been developed for determining nine benzoylureas (BUs) in fruit, vegetable, cereals, and animal products. Samples (5 g) were homogenized with diatomaceous earth and extracted in a 22 mL cell with 22 mL of ethyl acetate at 80°C and 1500 psi. After solvent concentration and exchange to methanol, BUs were analyzed by LC‐MS/MS using an IT mass analyzer, which achieved several transitions of precursor ions that increase selectivity providing identification. LOQs were between 0.002 and 0.01 mg/kg, which are equal or lower than maximum residue limits established by the Codex Alimentarius. Excellent linearity was achieved over a range of concentrations from 0.01 to 1 mg/kg with correlation coefficients 0.995–0.999 (n=7). Validation of the total method was performed by analyzing in quintuplicate seven different commodities (milk, eggs, meat, rice, lettuce, avocado, and lemon) at three concentration levels (0.01, 0.1, and 1 mg/kg). The recoveries ranged from 58 to 97% and the RSDs from 5 to 19% depending on the compound and the commodity. The combination of pressurized liquid extraction with LC‐MS/MS provides a sensitive and selective method for the determination of BUs in food.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raynie, D. E. (2004) · Analytical Chemistry · doi:10.1021/ac040117w · Cited by 195
Brito, N. M., Navickiene, S., Polese, L., Jardim, E. F. G., Abakerli, R. B., & Ribeiro, M. L. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00351-5 · Cited by 147
Cited by
LeDoux, M. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.12.097 · Cited by 287
Ionic liquids in solid-phase microextraction: A review
Ho, T. D., Canestraro, A. J., & Anderson, J. L. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.03.034 · Cited by 282
Ionic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84
Zeng, H., Qiao, K., Li, X., Yang, M., Zhang, S., Lu, R., Li, J., Gao, H., & Zhou, W. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700890 · Cited by 49
Peng, G., He, Q., Mmereki, D., Lu, Y., Zhong, Z., Liu, H., Pan, W., Zhou, G., & Chen, J. (2016) · Journal of Separation Science · doi:10.1002/jssc.201501347 · Cited by 27
Metadata
- Authors
- Brutti, M., Blasco, C., & Picó, Y.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2010-01
- Volume
- 33
- Issue
- 1
- Pages
- 1-10
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1994875323
- Cited by
- 157
- References
- 2
- FWCI
- 42.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC‐MS. https://app.cochat.ai/papers/10.1002/jssc.200900314
- The paper
- Brutti, M., Blasco, C., & Picó, Y. (2010). Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC‐MS. Journal of Separation Science. https://doi.org/10.1002/jssc.200900314
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.