Extraction of organophosphorus pesticides in water and juice using ultrasound‐assisted emulsification–mixroextraction
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In this study, a microextraction method termed as ultrasound‐assisted emulsification–microextraction (USAEME) has been developed for the extraction of organophosphorus pesticides (OPPs) in water and orange juice samples. In the USAEME method, aliquots of 50 μL chlorobenzene used as extraction solvent was added to 10 mL water sample in a conical glass centrifugal tube. Factors influencing the USAEME extraction efficiency such as sonication time, extraction solvent, extraction volume and salt addition were evaluated. Under the optimum conditions, enrichment factors ranged from 241 to 311, LOD varied from 5.3 to 10.0 ng/L and linearity with a coefficient of estimation (r2) varied from 0.9991 to 0.9998 in the concentration level range of 0.05–2.5 μg/L for the extraction of OPPs in water samples. Finally, the proposed USAEME method was used for the extraction of OPPs from water and orange juice. The recoveries were in the range of 80.0–110.0%, and the repeatability of the method expressed as RSD (n=3) varied between 1.6 and 13%. The USAEME method has the advantage of being easy to operate, low consumption of organic solvent and high extraction efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Ozcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
Cited by
Beyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Organophosphorus pesticides: Impacts, detection and removal strategies
Ajiboye, T. O., Oladoye, P. O., Olanrewaju, C. A., & Akinsola, G. O. (2022) · Environmental Nanotechnology, Monitoring & Management · doi:10.1016/j.enmm.2022.100655 · Cited by 118
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Farajzadeh, M. A., Sattari Dabbagh, M., & Yadeghari, A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700052 · Cited by 72
Farajzadeh, M. A., Abbaspour, M., Kazemian, R., & Afshar Mogaddam, M. R. (2020) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.10200 · Cited by 41
Bazmandegan‐Shamili, A., Dadfarnia, S., Shabani, A. M. H., Moghadam, M. R., & Saeidi, M. (2018) · Journal of Separation Science · doi:10.1002/jssc.201701427 · Cited by 25
Metadata
- Authors
- Jia, C., Zhu, X., Chen, L., He, M., Yu, P., & Zhao, E.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2010-02
- Volume
- 33
- Issue
- 2
- Pages
- 244-250
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2140127486
- Cited by
- 62
- References
- 6
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.