Ionic liquid/ionic liquid dispersive liquid–liquid microextraction
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this article, a novel and simple microextraction method, termed ionic liquid/ionic liquid dispersive liquid–liquid microextraction (IL/IL‐DLLME), has been designed and developed for the rapid enrichment and analysis of environmental pollutants. Instead of using hazardous organic solvents, two kinds of ILs, hydrophobic IL and hydrophilic IL, were used as extraction solvent and disperser solvent in IL/IL‐DLLME step, respectively. Permethrin and biphenthrin, two of the often‐used pyrethroid pesticides, were used as model compounds. Factors that may affect the enrichment efficiencies were investigated and optimized in detail. Under optimum conditions, permethrin and biphenthrin exhibited a wide linear relationship over the range 1–100 μg/L. For permethrin and biphenthrin, the precisions were 4.65–7.78%, and limits of detection were found to be 0.28 and 0.83 μg/L, respectively. Satisfactory results were achieved when the present method was applied to analyze the target compounds in real‐world water samples with spiked recoveries over the range 84.1–113.5%. All these facts indicated that IL/IL‐DLLME is a simple and rapid alternative for the enrichment and analysis of environmental pollutants and will have a wide application perspective in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Cited by
Niedermeyer, H., Hallett, J. P., Villar-Garcia, I. J., Hunt, P. A., & Welton, T. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35177c · Cited by 604
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Mixing ionic liquids – “simple mixtures” or “double salts”?
Chatel, G., Pereira, J. F. B., Debbeti, V., Wang, H., & Rogers, R. D. (2014) · Green Chemistry · doi:10.1039/c3gc41389f · Cited by 343
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“02 [1 68 ] Recent developments in dispersive liquid–liquid microextraction”
Recent advances of ionic liquids in sample preparation
Feng, J., Loussala, H. M., Han, S., Ji, X., Li, C., & Sun, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115833 · Cited by 164
Ionic liquids in the microextraction techniques: The influence of ILs structure and properties
Yavir, K., Konieczna, K., Marcinkowski, Ł., & Kloskowski, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115994 · Cited by 134
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“procedures that involve the use of ILs as extractant solvents, those which also use also an IL as the disperser solvent, in this case of a hydrophilic character (IL/IL-DLLME), should be mentioned (301, 465, 776, 949, 1016).”
MethodState-of-the-art on the technique of dispersive liquid-liquid microextraction
Wang, Q., Chen, R., Shatner, W., Cao, Y., & Bai, Y. (2019) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.08.010 · Cited by 86
Ionic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84
Farajzadeh, M. A., Sattari Dabbagh, M., & Yadeghari, A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700052 · Cited by 72
Metadata
- Authors
- Zhao, R., Wang, X., Li, F., Wang, S., Zhang, L., & Cheng, C.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2011-02-25
- Volume
- 34
- Issue
- 7
- Pages
- 830-836
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1982624106
- Cited by
- 58
- References
- 5
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.