Enrichment and sensitive determination of dichlorodiphenyltrichloroethane and its metabolites with temperature controlled ionic liquid dispersive liquid phase microextraction prior to high performance liquid phase chromatography
Abstract
Dichlorodiphenyltrichloroethane (DDT) and its main metabolites are important environmental pollutants and have been in the focusing center. It is of great value to develop simple, rapid, sensitive and easy to operate method for monitoring them. Present work established a novel temperature controlled ionic liquid dispersive liquid phase microextraction method in combination with high performance liquid chromatography for the enrichment and determination of DDT and its metabolites. Proposed method used only ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) for the enrichment and overcame the demerits of conventional single drop liquid phase microextraction and dispersive liquid-liquid microextraction. Temperature has two functions here, one is to promote the dispersing of ionic liquid into the solution and forming infinitesimal micro-drop and increasing the chance of the analytes extracted into ionic liquid phase, and the other one is to perform phase-separation. A series of factors that would affect the extraction performance was systematically investigated and optimized. The experimental results indicated that the detection limits obtained for p,p'-DDD, p,p'-DDT, o,p'-DDT and p,p'-DDE were 0.24, 0.24, 0.45, 0.24 ng mL(-1), respectively. The linear ranges for them were from 1.0 to 100 ng mL(-1), and the precisions were between 3.8% and 6.7% (n=6). The proposed method was validated with four real-world samples and excellent results were achieved.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In four IL-DLLME pesticide works, no disperser solvent was used (only the IL [HMIm][PF6]), because dispersion is temperature-assisted.
“We should mention that, in four of these works [13-16], no disperser solvent was used (only the IL [HMIm][PF6]), since the dispersion is temperature-assisted.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [16]
In most IL-DLLME pesticide works, water samples were analyzed using HPLC as the separation technique.
“In most cases, water samples have also been analyzed using HPLC as the separation technique [13-16,32,47].”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [16]
The temperature-controlled LPME variation has been applied using only ionic liquids as extractants.
“This variation of the technique has been applied using only ionic liquids (ILs) as extractants [13-16]”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [16]
For IL-DLLME of pesticides, a relatively small number of works has been published, especially in recent years.
“Regarding IL-DLLME of pesticides, a relatively small number of works has come out, especially in recent years [13-16,32,38,47,50].”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [16]
IL-DLLME has a drawback of a wide peak at the beginning of the chromatogram corresponding to the IL.
“As can be seen, at the beginning of the chromatogram, there appeared a wide peak, corresponding to the IL - one of the main drawbacks of using IL-DLLME, as already reported [14-19,32,38,47,50,65-67] -although, in this case, it did not interfere at all in the separation.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [16]
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · see citing works
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353 · see citing works
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333 · see citing works
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276 · see citing works
Dispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 267 · see citing works
The roles of ionic liquids in sorptive microextraction techniques
Aguilera-Herrador, E., Lucena, R., Cárdenas, S., & Valcárcel, M. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.009 · Cited by 171 · see citing works
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102 · see citing works
Application of ionic liquids for liquid–liquid microextraction
Zhang, P., Hu, L., Lu, R., Zhou, W., & Gao, H. (2013) · Analytical Methods · doi:10.1039/c3ay40597d · Cited by 50 · see citing works
- Authors
- Bai, H., Zhou, Q., Xie, G., & Xiao, J.
- Affiliations
- Henan Normal University (CN)
- Henan Institute of Science and Technology (CN)
- University of Science and Technology Beijing (CN)
- Corresponding author
- Zhou, Qingxiang
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2009-09
- Volume
- 651
- Issue
- 1
- Pages
- 64-68
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2068718361
- Cited by
- 67
- References
- 2
- Citations by year
- 2024: 1 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 5 · 2014: 5 · 2013: 8 · 2012: 12
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (020877022)
- High-Tech Research & Development Planning (863 Plan) of P.R. China (2006AA06Z424)
- Personal Innovation Foundation of Universities in Henan Province ([2005]126)
- Natural Science Foundation of Henan Province (092300410126)
- Fund of Henan Normal University (2006PL06)
- Henan Key Laboratory for Environmental Pollution Control
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Keywords
- DDT, DDT metabolites, ionic liquid extraction, 1-hexyl-3-methylimidazolium hexafluorophosphate, p,p'-DDD, p,p'-DDT, o,p'-DDT, p,p'-DDE, sample enrichment, environmental pollutants, pesticide residues
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review