Cited by 67Analytical chemistry methods developmentPesticide Residue Analysis and SafetyAnalytical Chemistry and Chromatography

Enrichment and sensitive determination of dichlorodiphenyltrichloroethane and its metabolites with temperature controlled ionic liquid dispersive liquid phase microextraction prior to high performance liquid phase chromatography

Bai, Huahua, Zhou, Qingxiang, Xie, Guohong, Xiao, Junping·2009·Analytica Chimica Acta

Abstract

Dichlorodiphenyltrichloroethane (DDT) and its main metabolites are important environmental pollutants and have been in the focusing center. It is of great value to develop simple, rapid, sensitive and easy to operate method for monitoring them. Present work established a novel temperature controlled ionic liquid dispersive liquid phase microextraction method in combination with high performance liquid chromatography for the enrichment and determination of DDT and its metabolites. Proposed method used only ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) for the enrichment and overcame the demerits of conventional single drop liquid phase microextraction and dispersive liquid-liquid microextraction. Temperature has two functions here, one is to promote the dispersing of ionic liquid into the solution and forming infinitesimal micro-drop and increasing the chance of the analytes extracted into ionic liquid phase, and the other one is to perform phase-separation. A series of factors that would affect the extraction performance was systematically investigated and optimized. The experimental results indicated that the detection limits obtained for p,p'-DDD, p,p'-DDT, o,p'-DDT and p,p'-DDE were 0.24, 0.24, 0.45, 0.24 ng mL(-1), respectively. The linear ranges for them were from 1.0 to 100 ng mL(-1), and the precisions were between 3.8% and 6.7% (n=6). The proposed method was validated with four real-world samples and excellent results were achieved.

Integrity signals

Registry

Crossref · 10.1016/j.aca.2009.08.011

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In four IL-DLLME pesticide works, no disperser solvent was used (only the IL [HMIm][PF6]), because dispersion is temperature-assisted.

    “We should mention that, in four of these works [13-16], no disperser solvent was used (only the IL [HMIm][PF6]), since the dispersion is temperature-assisted.”
  • In most IL-DLLME pesticide works, water samples were analyzed using HPLC as the separation technique.

    “In most cases, water samples have also been analyzed using HPLC as the separation technique [13-16,32,47].”
  • The temperature-controlled LPME variation has been applied using only ionic liquids as extractants.

    “This variation of the technique has been applied using only ionic liquids (ILs) as extractants [13-16]”
  • For IL-DLLME of pesticides, a relatively small number of works has been published, especially in recent years.

    “Regarding IL-DLLME of pesticides, a relatively small number of works has come out, especially in recent years [13-16,32,38,47,50].”
  • IL-DLLME has a drawback of a wide peak at the beginning of the chromatogram corresponding to the IL.

    “As can be seen, at the beginning of the chromatogram, there appeared a wide peak, corresponding to the IL - one of the main drawbacks of using IL-DLLME, as already reported [14-19,32,38,47,50,65-67] -although, in this case, it did not interfere at all in the separation.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bai, H., Zhou, Q., Xie, G., & Xiao, J.
Affiliations
  • Henan Normal University (CN)
  • Henan Institute of Science and Technology (CN)
  • University of Science and Technology Beijing (CN)
Corresponding author
Zhou, Qingxiang
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2009-09
Volume
651
Issue
1
Pages
64-68
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2068718361
Cited by
67
References
2
Citations by year
2024: 1 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 5 · 2014: 5 · 2013: 8 · 2012: 12
FWCI
11.36
Type
journal article
Language
en
Open access
closed
Locations
  • Analytica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (020877022)
  • High-Tech Research & Development Planning (863 Plan) of P.R. China (2006AA06Z424)
  • Personal Innovation Foundation of Universities in Henan Province ([2005]126)
  • Natural Science Foundation of Henan Province (092300410126)
  • Fund of Henan Normal University (2006PL06)
  • Henan Key Laboratory for Environmental Pollution Control
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
DDT, DDT metabolites, ionic liquid extraction, 1-hexyl-3-methylimidazolium hexafluorophosphate, p,p'-DDD, p,p'-DDT, o,p'-DDT, p,p'-DDE, sample enrichment, environmental pollutants, pesticide residues

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review