Ultrasound‐assisted emulsification microextraction based on solidification of floating organic droplet combined with HPLC‐UV for the analysis of antidepressant drugs in biological samples
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Ultrasound‐assisted emulsification microextraction based on the solidification of floating organic droplet combined with high‐performance liquid chromatography‐ultra violet (HPLC‐UV) detection was applied for the extraction and determination of fluoxetine, citalopram, and venlafaxine as antidepressants drugs in biological samples. In total, 30 μL of undecanol was injected slowly into a glass‐centrifuge tube containing 5 mL alkaline sample solution that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and the fine droplets of solvent were floated at the top of the test tube. The test tube was then cooled in an ice bath and the solidified solvent transferred into a conical vial; it melted quickly at room temperature. Then the analysis of the extracts was carried out by high‐performance liquid chromatography. Under optimal conditions, the preconcentration factors were between 174 and 316. Detection limits (LODs) of 3 μg/L were obtained and the calibration graphs were linear within the range of 10–1000 μg/L. Finally, the feasibility of the proposed method was successfully confirmed by extraction and determination of the antidepressant drugs in human urine and plasma samples in the range of microgram per liter and suitable results were obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Cited by
Modern solutions in the field of microextraction using liquid as a medium of extraction
Płotka-Wasylka, J., Owczarek, K., & Namieśnik, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.08.010 · Cited by 109
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“Antidepressant drugs Plasma, urine USAEME-SFO HPLC-UV 3 mg L¡1 (73)”
MethodRecent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Vera-Avila, L. E., Rojo-Portillo, T., Covarrubias-Herrera, R., & Peña-Alvarez, A. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.052 · Cited by 71
Yurdakok-Dikmen, B., Kuzukiran, O., Filazi, A., & Kara, E. (2016) · Journal of Water and Health · doi:10.2166/wh.2015.177 · Cited by 23
Metadata
- Authors
- Ebrahimzadeh, H., Saharkhiz, Z., Tavassoli, M., Kamarei, F., & Asgharinezhad, A. A.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2011-04-13
- Volume
- 34
- Issue
- 11
- Pages
- 1275-1282
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2148023862
- Cited by
- 59
- References
- 3
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.